The Thermo Scientific™ iCE™ 3000 Series AAS enables simple measurement of elements in a wide range of samples such as Water, Soil, Sludge, Milk, Fertilizer, Animal Feed, Forages. The flame atomizer is ideal for the measurement of high concentration samples, whilst the furnace atomizer achieves sub ppb detection.
Manufacturer | Thermo Fisher Scientific | Funding Source | UGC Special Grant |
Model | iCE 3000 | Whether the equipment service can be provided to external researchers/institutions | Yes |
Manufactured Year | 0000 | Availability of Technically Competent Staff | Yes |
HS Code | Instrument Condition | Partly malfunctioning | |
Vendor Name | Analytical Instrument (Pvt)Ltd | Commencement of Operations Date | |
Vendor Contact | InstrumentPrice | 0.00 | |
Vendor Url | Stage of the Record | Completed | |
Catalog Aceess | |||
Catalog Upload | View File | ||
Catalog Link | https://assets.thermofisher.com/TFS-Assets/CMD/brochures/br-44364-aas-ice-3000-br44364-en.pdf |
Institute | Wayamba University of Sri Lanka |
Faculty | Faculty of Livestock, Fisheries & Nutrition |
Department | Livestock and Avian Sciences |
Laboratory | Common Laboratory - DLAS |
Contact Person Name | HOD- Dr. (Mrs.) H.N.N. Dilrukshi, Technical Officer - Mrs. Wajira Ginigaddara |
nadeeshadilrukshi@wyb.ac.lk , wajiraginigaddara@gmail.com | |
Phone Number | 0312299873 |
Mobile Number |
Product Category | Spectroscopy |
Sub Category | UV-Visible Spectrometer |
Testing Paremeters | Optical absorption or transmittance of liquids, solids and thin-films |
Description | UV-Vis spectroscopy is an analytical technique that measures the amount of discrete wavelengths of UV, visible or IR light that are absorbed by or transmitted through a sample in comparison to a reference or blank sample. |
Relevant Instruments | shimadzu uv-vis 1800 double-beam spectrophotometer |
Technical Specification | iCE 3300 Spectrometer AA Spectrometer with wide range photomultiplier. 6 Lamp Automatic Carousel. Flame and/or Furnace options available. Light Source Single or multi-element hollow cathode lamps. Uncoded and Data Coded hollow cathode lamps. 6 independent lamp supplies, each providing 0 to 20 mA. Wavelength Range 180 nm to 900 nm. Data/Control Systems Spectrometer 512 kB Flash PROM. 256 kB RAM. 3 general purpose RS232C ports. USB Port Monochromator Ebert configuation with nominal 0.2, 0.5 and 1.0 nm spectral bandwidths. Half height slit settings available. Reciprocal linear dispersion 1.5 to 2.0 nm/mm. Focal length 270 mm. Grating 1800 l/mm Absorbance Range -0.150 A to 3.000 A (including background signal). Background Correction Quadline (continuum source) is standard on all spectrometers. Background signals <2 A corrected to <2 %. Total signal up to 3 A. Gas Control Fuel Flow Range Air/Acetylene - 0.8 to 2.3 l/min. Nitrous Oxide/Acetylene - 3.6 to 5.1 l/min. |
Number of samples per cycle | 60 |
Number of samples per day | 0 |
Total usage hour per day | 0 |