The Cytek Northern Lights is a full-spectrum flow cytometer designed to offer high flexibility, sensitivity, and affordable multicolor analysis. Using spectral detection and advanced unmixing algorithms, it captures the complete emission profile of each fluorochrome, enabling efficient resolution of overlapping dyes and expanded panel design. It provides high-quality data for immunophenotyping, functional assays, and complex multicolor experiments while maintaining ease of use. With its compact design and cost-effective performance, the Northern Lights is well suited for research labs seeking versatile spectral cytometry.
| Manufacturer | Cytek |
| Model | Northern Lights |
| Manufactured Year | 0000 |
| HS Code | — |
| Instrument Condition | Functioning well |
| Instrument Price (Rs) | 0.00 |
| Funding Source | — |
| External Research Support | Yes |
| Availability of Technical Staff | Yes |
| Commencement of Operations | — |
| Vendor Name | — |
| Vendor Contact | — |
| Vendor URL | — |
| Catalog Access | — |
| Catalog Upload | — |
| Catalog Link | — |
| Stage of the Record | Completed |
Please sign in to view the contact details of this instrument and its owner.
Login to View Contact DetailsAccount access is restricted to registered users. Register now for free.
| Testing Service | Flowcytometry |
| Sub Category | Flowcytometry Analysis, Enzyme Linked Immunosorbent Assay (ELISA), Rapid Antigen Test (RAT) Development, Multimode Plate Reader Analysis, SDS-PAGE & Western Blots |
| Testing Parameters | — |
| Description | Flowcytometry Analysis Enzyme Linked Immunosorbent Assay (ELISA) Rapid Antigen Test (RAT) Development Multimode Plate Reader Analysis SDS-PAGE & Western Blots |
| Relevant Instruments | Cytek Northern lights |
| Technical Specification | <h3>Key Technical Specifications</h3> <ul> <li> <p><strong>Laser configurations:</strong> 1–3 lasers</p> <ul> <li> <p>3-laser: 405 nm (100 mW), 488 nm (50 mW), 640 nm (80 mW)</p> </li> </ul> </li> <li> <p><strong>Detection capability / Colors:</strong></p> <ul> <li> <p>Up to <strong>24+ colors</strong> with 3-laser system</p> </li> </ul> </li> <li> <p><strong>Detectors:</strong></p> <ul> <li> <p>Utilizes proprietary high-sensitivity semiconductor arrays (CWDM) per laser for spectral detection across a broad emission range (≈ 420–829 nm) — no filter swapping required when changing fluorochromes.</p> </li> <li> <p>Module breakdown (for three-laser config): “Violet” module — 16 channels; “Blue” module — 14 channels; “Red” module — 8 channels.</p> </li> </ul> </li> <li> <p><strong>Fluidics & Throughput:</strong></p> <ul> <li> <p>Sample flow rates: low 15 μL/min, medium 30 μL/min, high 60 μL/min; optional plate-based high-throughput mode up to 100 μL/min.</p> </li> <li> <p>Supports manual tubes (12 × 75 mm) and optionally 96-well plates (with plate loader accessory).</p> </li> <li> <p>Data acquisition rate: up to ~ 35,000 events per second (three-laser system).</p> </li> <li> <p>Carryover (tube mode) typically < 0.1%.</p> </li> </ul> </li> <li> <p><strong>Optics & Scatter Detection:</strong></p> <ul> <li> <p>Forward Scatter (FSC): high-performance semiconductor detector with 488 nm bandpass filter.</p> </li> <li> <p>Side Scatter (SSC): detectors available for 405 nm and 488 nm side scatter (405 nm SSC only in systems with the violet laser).</p> </li> <li> <p>Sensitivity: capable of resolving small particles (e.g. 0.2 µm beads from noise).</p> </li> </ul> </li> <li> <p><strong>Optical & Spectral Performance:</strong></p> <ul> <li> <p>Fixed optical assembly — no need to change optical filters when changing fluorochromes.</p> </li> <li> <p>Full-spectrum detection + unmixing for fluorochromes with overlapping emission spectra (e.g. APC vs Alexa 647) — enables flexible design of multicolor panels.</p> </li> </ul> </li> </ul> |
| Number of Samples per Cycle | 0 |
| Number of Samples per Day | 0 |
| Total Usage Hours per Day | 0 |
Login required. Sign in to rate this instrument and share your feedback.
Login to Give Feedback