Institute Name | Product Category/ Test Name (Matrix) | Sub Category | Testing Parameters | Description | Relavant Instruments | |
---|---|---|---|---|---|---|
1 | University of Jaffna | Conductivity, Salinity, TDS and pH | ||||
2 | University of Jaffna | Optical Characterization | ||||
3 | University of Jaffna | Concentration of Ions | ||||
4 | University of Jaffna | Electrochemical Characterization | ||||
5 | University of Jaffna | Incubation | ||||
6 | University of Jaffna | Separation technique | ||||
7 | University of Jaffna | Structural Characterization | ||||
8 | University of Moratuwa | computer and software | ||||
9 | University of Moratuwa | Computers and Software | ||||
10 | University of Colombo | 1. Biological Fluids (Plasma/Serum) | 1. Biological Samples Blood (Plasma/Serum).Ex; Lipid Profile, Liver Profile, Serum Electrolytes. | Name - BA-88AModel - Mindray Semi Automated Analyzer Serial Number - WR-43013994 | ||
11 | University of Colombo | pharmaceutical dosage forms | Dissolution Profile Testing, Multi-Media Testing Quality Control (Batch-to-Batch Consistency),Comparative Dissolution Testing (Bioequivalence), |
|
Dissolution apparatus ( Pharma Test ) | |
12 | University of Colombo | Pharmaceutical Samples, Biological Samples | Food and Beverages, Environmental Samples, Forensic Samples, Cosmetics and Personal Care Products,. Industrial Samples | 1. Pharmaceutical Samples Active Pharmaceutical Ingredients (APIs): Used for purity testing, impurity profiling, and degradation product identification. Formulated Drugs: To assess the stability, quality control, and release profiles in pharmaceutical development. Pharmacokinetics/Pharmacodynamics Studies: Analysis of drugs and metabolites in biological matrices. 2. Biological Samples Blood (Plasma/Serum): For drug concentration measurement, metabolomics, and clinical diagnostics. Urine: Frequently used for drug testing, toxicology studies, and metabolic profiling. Tissue (Biopsy or Animal Tissues): For studying drug distribution, tissue-specific metabolism, or lipid profiling. 3. Food and Beverages For detecting pesticide residues, veterinary drug residues, and food additives. Used to analyze preservatives, contaminants, and natural compounds. 4. Environmental Samples Water (Surface, Groundwater, and Wastewater): Analyzed for pollutants, pharmaceutical residues, and organic contamina | LCMS/MS 8030 | |
13 | University of Moratuwa | Analytical instrument(Refractive index) | Liquids | |||
14 | University of Moratuwa | Analytical instrument(Octane Value) | Petroleum products | |||
15 | University of Moratuwa | Analytical instrument(Moisture content) | Moisture content | |||
16 | Sri Lanka Standards Institution | Yarn/Sewing tread | Nylon yarn, Spun polyester sewing tread, Twine rope, jute yarn | Tesile properties, Elongation, Text, TKT No., |
Dermination of properties of sewing tread Tensle & elongation properties |
Crimp Tester, Universal tensile machine |
17 | Sri Lanka Standards Institution | Adhesive & Sanitory test solutions | Artificial blood liquid, Artificail urine solution, Adhesives, Natural Rubber latex | Viscosity, pH |
Testing of pH and Viscosity |
Brookfield Viscometer |
18 | Sri Lanka Standards Institution | Paper & Board | Photocopy papers, typing papers, Cardboards, Craft papers, Craft paper bags | Tensile Strength, tearing force, GSM, Busting Strength, Water Absorption(Cobb test) |
Papers & board testing for following parameters for factory QC purposes and tender evaluations Tensile Strength, tearing force, GSM, Busting Strength, Water Absorption(Cobb test)
|
Elmendrof tearing tester, Tensile tester, Cobb tester |
19 | Sri Lanka Standards Institution | Electric Ceiling Fan (1400 mm) Energy Efficiency rating | Electric Ceiling Fan, Size 1400 mm | Energy Efficiency Rating | Electric Ceiling fan Energy Efficiency Rating test setup | |
20 | Sri Lanka Standards Institution | Lamps for general Lighting Services | Minimum Energy Performance for LED | Minimum Energy Performance requirements (Luminous flux, CCT, CRI) | Integrating Sphere with Spectroradiometer | |
21 | Sri Lanka Standards Institution | Lamps for general Lighting Services | LED Lamps | Performance requirements (Luminous flux, CCT, CRI, SDCM) | Integrating Sphere with Spectroradiometer | |
22 | Sri Lanka Standards Institution | Alcoholic Drink | Toddy | Trace and Heavy metals: As, Pb, Cd, Hg , Methanol content, Ethanol content | Inductively Coupled Plasma Mass Spectrometry (ICP-MS), Gas Chromatography Flame Ionization Detector (GC-FID), Refrigerated centrifuge | |
23 | SGS Lanka (PVT) Ltd | Textile Products | Textile Chemical Testing | Phthalate, Azo Dyes, Organotin, Chlorinated Organic Compound, DmFa, DmFu, | ||
24 | Sri Lanka Standards Institution | Liquid Petroleum Gas (LPG) | Liquid Petroleum Gas (LPG) | Vapour pressure, Propane content, Butane content, C5 and higher HC content, Dienes content, Alkynes content, Relative density | Liquid Petroleum Gas (LPG) Analyzer | |
25 | University of Moratuwa | Textile Manufacture | Knitting Machines | Knitting Machines |
Introduction to the machine tools required to make textiles through the knitting method. |
Knitting Machines |
26 | Sri Lanka Standards Institution | Product | Food, Water, Cosmetics, Fertilizers | Microbiology parameters | ||
27 | Sri Lanka Standards Institution | Polymer and Textile | Feeding bottles made of polymer, Safety of toys, Reusable plastic bottles for carrying drinkable liquids, Textile materials | Phthalates, Trace and Heavy Metals / Migration of Certain elements: As, Cr, Hg, Cd, Pb, Sb, Ba, Co, Fe, Li, Mn, Zn | Inductively Coupled Plasma - Mass Spectrometer (ICP-MS), Gas chromatography mass spectrometry (GC-MS/MS)Shaking water bath, pH meter, | |
28 | Sri Lanka Standards Institution | Speciation Analysis | Canned fish, Raw fish, Animal feed, Infant Cereal | Arsenic(III), Arsenic(V), Inorganic Arsenic | Inductively Coupled Plasma - Mass Spectrometer (ICP-MS) coupled with High-performance liquid chromatography(HPLC), Refrigerated Centrifuge, Water bath, Vortex mixer | |
29 | Sri Lanka Standards Institution | Cosmetics (Volatile substances) | Baby cologne, Perfume and Toilet waters, Hand sanitizers, Cologne | Alcohol content (Ethanol content, Methanol content, 2-Propanol content), Cloudiness, pH, Stability of Smell | Flame Ionization Detector - Gas Chromatography (GC-FID), Refrigerated Centrifuge, pH meter | |
30 | Sri Lanka Standards Institution | Cosmetics (Trace and Heavy metals) | Skin cream and lotion for babies, Skin powder for babies, Baby cologne, Baby oil, Tooth paste, Skin powders, Hair creams, Skin cream and lotion, Synthetic laundry powder, Hair oil, Lipstick, Perfume and Toilet waters, Hand sanitizers, Shampoo | Trace and Heavy metals: As, Pb, Cd, Hg, Sb | Inductively Coupled Plasma - Mass Spectrometer (ICP-MS), Microwave Digestion. | |
31 | Sri Lanka Standards Institution | Fertilizer (Trace and Heavy metals) | Urea, Ammonium sulphate (SOA), Potassium chloride (MOP), Ground rock phosphate, Triple super phosphate (TSP), Dolomite, Magnesium sulphate monohydrate, Compost from municipal solid waste, Compost from raw agricultural origin, Liquid organic fertilizer, | Trace and Heavy metals: As, Pb, Cd, Cr, Ni | Inductively Coupled Plasma - Mass Spectrometer (ICP-MS), Microwave Digestion. | |
32 | Sri Lanka Standards Institution | Food (Trace and Heavy metals) | Cereal based products. Fish and meat products, Fats and oil based products, Sugar based products, Fruits and vegetable based products, Spices, Soft drinks, Milk based products, Legume based products | Trace and Heavy metals: Pb, Cd, Hg, As, Cr, Cu, Sn | Inductively Coupled Plasma - Mass Spectrometer (ICP-MS), Microwave Digestion | |
33 | Sri Lanka Standards Institution | Water Quality | Bottled drinking water, Source water, Natural mineral water, Portable water | Pesticides residues, Trace and Heavy metals: As, Pb, Cd, Hg, Cr, Mn, Ni, Se, Al, Zn, Cu, Ba, Sb, Fe | Inductively Coupled Plasma - Mass Spectrometer (ICP-MS), Gas chromatography mass spectrometry (GC-MS/MS) | |
34 | Sri Lanka Standards Institution | Food Products | Edible oils and fat | Fatty Acid Profile |
Testing of Fatty acid profile according to ISO and SLS test methods. |
GC-FID/ECD |
35 | Sri Lanka Standards Institution | Food Products | Edible oils and fat, Nuts, Spices, Flour & Flour products, Cereals & Pulses, Process Cereal based food, Fruit, Vegetable and Agriculture based Products,Beverages, Frozen confections | Aflatoxin, Benzoic acid and Sorbic acid, Caffeine, Sudan Dyes, Sugar Profile |
Testing of Aflatoxin, Benzoic acid and Sorbic acid and Caffeine, Sudan Dyes, Sugar Profile |
UHPLC, Vacuum Manifold, Rotary Evaporator, Shaker, Sonicater, Fume Cupboard |
36 | University of Moratuwa | Determination of Mechanical Stability Time of Latex | ||||
37 | University of Moratuwa | prepairing distilled water | ||||
38 | University of Moratuwa | Distilled Water Plant | prepairing distilled water | |||
39 | University of Moratuwa | Basic Process Principles | ||||
40 | University of Moratuwa | Analytical instrument(flash point) | Petroleum products | |||
41 | University of Sri Jayewardenepura | General Laboratory Equipment | ||||
42 | The Adolescent and Adult Thalassemia Care Unit | blood | blood, plasma, serum | G6PD enzyme, PK enzyme, GPI enzyme |
The spectrophotoeter is used to analyse kinetic reaction of enzymes in human blood. |
Double-beam uv-visible spectrophotometer |
43 | University of Moratuwa | Workstation Computer | ||||
44 | University of Moratuwa | Abrasion Tester | determination of abrasion resistance | |||
45 | University of Moratuwa | Melt Flow Index | determination of melt flow index | |||
46 | University of Moratuwa | Textile Manufacturing | Spinning | |||
47 | University of Moratuwa | Linear Motor and accessories | DC Voltage, Current, PWM |
This linear motor and a servo motor driver are used for precision linear motions. A linear encoder, read by a DAQ card, is used to accurately identify the motor's position. |
||
48 | University of Moratuwa | Measuring(Calorific value) | ||||
49 | University of Moratuwa | Waste Water treatment | COD,BOD,TSS,TDS,VSS | COD Reactor, BOD Apparatus | ||
50 | University of Moratuwa | Analytical instrument(Vacuum distillation) | Petroleum products | |||
51 | University of Moratuwa | Motor and Accessories | Linear Motor and Accessories | DC Voltage, Current, PWM |
This linear motor and a servo motor driver are used for precision linear motions. A linear encoder, read by a DAQ card, is used to accurately identify the motor's position.
|
|
52 | University of Kelaniya | Chromatography | Iron Chromatograpy | water | ||
53 | University of Kelaniya | Chromatography | LCMS | pestiside | ||
54 | University of Kelaniya | ICP MS | Hevy metals | |||
55 | University of Kelaniya | Chromatography | Gas chromatography | Fatty acid | ||
56 | University of Kelaniya | spectroscopy | Plate reader | Absorbance reading | ||
57 | University of Moratuwa | Analytical instrument(flash point) | Liquids(Petroleum products) | |||
58 | University of Moratuwa | Centrifugation | liquid | |||
59 | University of Moratuwa | Measuring | Density of solid and liquid | |||
60 | University of Moratuwa | Analytical instrument | Elemental analysis of sodium through uranium in solid,lquids and powder samples as well as thin film coatings on solid substrates. | |||
61 | University of Colombo | Microscopy | Fluorescents | |||
62 | University of Ruhuna | Triaxial Appratus | Shear strength parameters |
Unconsolidated Undrained (UU) Triaxial tests can be performed. |
||
63 | Rajarata University of Sri Lanka | Nitrogen content of substances | Protein, Nitrogen, Digestion, Titrations,Ammonia, Conversion, Quantification | Crude protein content |
To determining the nitrogen content in organic compounds, which is a crucial measure for various applications, particularly in food, animal, agriculture, and environmental science. |
Kjeldahl Nitrogen Protein Analyzer |
64 | Rajarata University of Sri Lanka | Continuous fat extraction system | Food, feed, plant and animal specimens | Crude fat content |
Solvent extractor (soxhlet extraction) extracts soluble compounds from solid and semi-solid samples by continuously cycling a solvent through boiling, condensing, and dripping onto the food and feed sample. This repeated process efficiently isolates the desired substances into the solvent, which is then evaporated to recover the compounds. It is commonly used in various analytical applications. |
Solvent extractor/Soxhlet fat extraction unit/ fat extraction unit/ solvent fat extraction unit |
65 | Rajarata University of Sri Lanka | Energy/ heat released during a combustion reaction | Food, feed, plant and animal specimens | Energy value |
To measure the heat of combustion of a substance, typically for determining the energy content of food, feeds, or other materials in quantities of calories or Joules. |
Bomb calorimeter |
66 | Rajarata University of Sri Lanka | Sequential extraction of insoluble fibrous components | Food, feed, plant and animal specimens | Crude fiber content |
To determine the fiber content in various materials, typically in food, feed and agricultural products. The primary purpose of this unit is to isolate and quantify crude fibers, which are crucial for nutritional analysis, quality control, and research. |
Fiber Analyzer/ Fiber extraction unit |
67 | Uva Wellassa University | Metal | Steel, Composite | Non destruction testing apparatus | Eddy Current Tester | |
68 | Institute of Biochemistry Molecular and Biotechnology, University of Colombo | Sterelization | Autoclaving | Autoclave( AstellAMA260-N ) | ||
69 | University of Moratuwa | Food Processing | ||||
70 | University of Moratuwa | Drying | ||||
71 | University of Moratuwa | Test and Measurement Equipment | ||||
72 | University of Moratuwa | Spectroscopy | ||||
73 | University of Moratuwa | Microscopy | ||||
74 | University of Moratuwa | Meters, Monitors and Electrochemical Equipment | ||||
75 | University of Moratuwa | Information Technology | ||||
76 | University of Moratuwa | General Laboratory Equipment | ||||
77 | University of Moratuwa | Gases, Materials, Standards | ||||
78 | University of Moratuwa | Filtration and Water Purification | ||||
79 | University of Moratuwa | Chromatography | ||||
80 | University of Moratuwa | Analytical Instrument | ||||
81 | University of Moratuwa | Testing | Rubber testing | Rheological properties | ||
82 | University of Moratuwa | Processing | Rubber Processing | |||
83 | University of Moratuwa | Energy | ||||
84 | University of Sri Jayewardenepura | Cadavers | Phenoxyethanol‐based embalmed cadavers, Fresh cadavers | Hands on Training Simulation in Surgery |
Formaldehyde is "carcinogenic to humans" based on sufficient evidence it can cause nasopharyngeal cancer and leukemia. Currently the Department of Anatomy, FMS,USJ is shifting away from the tradional Formaldehyde based cadaver preservation to non Formaldehyde based cadaver preserrvation to minimise the exposure to the Formaldehyde. Cadavers are preserved using a non-formaline - Phenoxyethanol‐based embalming technique for the trainings to improve practical skills or learn new surgical techniques through interactive case discussions and an open approach to innovations and the introduction of new techniques among surgeons and surgical trainees. |
Corpse Preservation Freezer Lockers with Hand Lifter, Rapid Embalming Machine, Slow Embalming apparatus, High-speed band saw, Meat slicer, Dissection tool kits, Chest Freezer, ethanol pumps |
85 | University of Kelaniya | Antioxidants | Phenolics, Flavonoids | |||
86 | Ceylon Petroleum Storage Terminal Limited | Petroleum Products | Petrol, Diesel, JET A-1, Kerosene | Density, Viscosity | ||
87 | Sri Lanka Standards Institution | Umbrella | Umbrella cloth, Umbrella ribs, folding umbrella, non-folding umbrella. | Fabric Tensile strength, tearing strength, Colour fastness to water, Colour fastness to light, construction properties and dimensions of the umbrella ribs a |
Tesing of Umbrella ribs and umbrella cloth for the SLS and ISO standards. |
Xenon light fastness tester, Rota wash colour fastness tester, Universal tensile tester, |
88 | Sri Lanka Standards Institution | Sanitary products | Sanitary napkins, Panty liners, Baby Diapers, adult diapers | Absorbency, Re wet under load, pH, Ash content, Moisture content, Total absorption capacity. |
Determination of all performance parameters for sanitory products as well as micro biological parameters. Issue test report as per the NMRA regulations. |
Analytical balance, Thickness gauge, Electric Oven. |
89 | Sri Lanka Standards Institution | Polythene/plastic | polythene garbage bag, Polythene Grocery bag, Lunch sheet, | Thickness, Tensile strength, Tearing Strength, Mass per area, dimension. |
Determination of performance parameters and dimensions. |
Universal tensile tester, Micrometer, Analytical balance |
90 | Sri Lanka Standards Institution | Coated fabrics | Tarpoulin, PU coated Nylon, Umbrella cloth | Tensile strength, tearing strength, mass per unit area, Thickness, Water penetration test, Water repellence test |
Determination of performance parameter such as tensile, tearing, water penetration and water repellency. Carry out thickness and mass per unit area. |
Universal Tensile tester, Bumdusman Rain shower test, Water repellency tester, Thickness gauge. |
91 | Sri Lanka Standards Institution | Shoes Testing | Leather shoes, Sports/ Deck shoes, Gum boot, Riding boot, School Shoes | Abrasion resistance, Bonding Strength(Teo & back), Whole Shoe flexing , Sole flexing test, Sole material identification |
Determination of performance parameters of shoe such as abrasion, bonding strength and flexing. Determination of upper materials and sole materilas, carryout the dimension test of upper, counter and sole materials. |
DIN abrasion tester, Whole shoe testing machine, Whole sole testing machine, Bonding tester, Thickness gauge. |
92 | Sri Lanka Standards Institution | Textile/Fabric | Garments, Fabric, Towels | Breaking force, Tearing Force, GSM, pH, Colour fastness to light, Colour fastness to water, Crease Recovery, Skewness, Shrinkage on washing |
Determination of fabric performance parameters, colour fastness properties. For garments dimensional change in washine, pilling testing. |
Tensile testing machine, Xenon Colour fastness Tester, pilling tester, pH meter, |
93 | Wayamba University of Sri Lanka | Tissue sectioning |
This instrument used to repeatedly slice tissue into thin, uniform sections for downstream laboratory processing and imaging. |
Microtome | ||
94 | Wayamba University of Sri Lanka | Product Texture | Compression Platens use for test on self supporting products such as Cheese, Ice cream and gels | Cohesiveness, Hardness, Chewiness, Gumminess |
TX-700: An advanced, high-precision texture analyzer designed for the rigorous demands of research and quality control in various industries, including food, pharmaceuticals, cosmetics, and materials science. The new TX-700 is entirely equipped with one 7'' color touch screen. It is giving you a greater comfort to work and a clear view of data and results of analysis and curves without external software. |
|
95 | Wayamba University of Sri Lanka | Evaporating and condensing solvents and suspensions. |
The rotary evaporator is used for the evaporation and condensing of solvents using a rotating evaporating flask under vacuum. Distillation under vacuum increases capacity and is gentler on the product. Allowed to use only for food samples. |
Rotary evaporator | ||
96 | Wayamba University of Sri Lanka | Freeze drying |
Freeze Dryer is used to dry products under low temperature and vacuum without damaging their chemical structures. Allowed to use only for food samples. |
Freeze dryer | ||
97 | Wayamba University of Sri Lanka | Microscope | Inverted microscope | Live cell observation, Cell screening, Cell sampling and handling |
Inverted microscope is used for observing cells and organisms in cultures, petri dishes, flasks, microplates. This microscope is equipped with brightfield and often phase contrast which allows unstained transparent tissue to be observed more clearly. |
Inverted microscope |
98 | University of Peradeniya | Sample Preparation | Mixing | Orbital Shaker, Muffle Furnace | ||
99 | University of Peradeniya | Water Analyses | Anions in waater | Cl, F, Br, Sulfate, Phosphate, Nitrate | Ion chromatograph, Visible spectrometer | |
100 | University of Peradeniya | Sample Digestion |
Digesting solid or liquid samples for chemical analysis |
ICP, AAS, | ||
101 | University of Peradeniya | Particle Analyses | Particle size of materials |
Particle size of materials |
Laser Particle size Analyzer , Sieve Shaker | |
102 | University of Peradeniya | Imaging | Suface feature analysis | Surface features |
Obtaining images |
Scanning Electron Microscope, Polarizing Microscopes, Epi-fluorescent Microscope |
103 | University of Peradeniya | Elemental Analysis | Water Quality Analysis | Major, trace and ultra-trace element analysis | Inductively Coupled Plasma, Atomic Absorption Specrometry | |
104 | Industrial Technology Institute (ITI) | Processing Technology | Improve the appeareance of rice, Improve the quality of rice |
For buffering or polishing kernels of rice to chsnge their apprarance, taste and texture |
||
105 | Industrial Technology Institute (ITI) | Sound and vibration FFT analysis | Sound intensity measurements, Noise source identification |
B&K 2270 Sound Level Meter is flagship measuring instrument and analyzer. Equipped with two microphones, or two accelerometers, or one of each, B&K Type 2270 offers all the functionality as Type 2250 - with the addition of being capable of simultaneous measurements. In addition, tight phase matching between the two channels, allow Type 2270 to be used as a sound intensity analyzer. |
||
106 | Sri Lanka Institute of Textile & Apparel (SLITA) | Textile | Fibre, Polyester, Banana stem | Fibre Extraction, Polyester Dyeing , Longitudinal view, Banana stem cutting | Fibre Extraction Machine , Hightemperature High Pressure Machine , Light Microscope , Stem Cutter | |
107 | Gem and Jewellery Research and Training Institute (GJRTI) | Gems, Gemstones and Doamond | Natural and synthetic gems, | particle size analysis, vibrational energy, material identification, spectra analysis, elemental analysis, magnetic susceptibility, grinding | X-Ray Floresence Spectroscopy, Sieve Analysis, Isodynamic magnetic separator, Planetary ball milling, FTOR, Laser particle size analyzer, Raman Spectroscopy, UV-Vis Spectroscopy | |
108 | Lanka Mineral Sands Ltd | MInerals | Ilmenite, Rutile , Zircon | Ilmenite, Rutile , Zircon | ED XRF Analyzer | |
109 | Industrial Development Board (IDB) | Microbiological Analysis | Aerobic Plate Count, Yeast & Mould, Coliform, E-Coli, Salmonella, Staphylococcus | Autoclave, Incubator, Cooled Incubator, Water Bath with Shaking Device, Trincocular Microscope, Dry Air Oven, Advanced Vortex Mixer, Analytical Balance, Microwave Oven, Electric Sterilizer, Bio Safety Cabinet, Colony Counter, Dual Leaser IR Thermometer, Heating Magnetic Stirrers, Refrigerator | ||
110 | Industrial Development Board (IDB) | Food | Water activity, Shelf-life, pepper | Moisture, Protein, Aflatoxin, piperine, total ash, acid insoluble ash, crude fiber, total fat, pH, Colour, sucrose, brix value | Moisture oven, Universal oven, Vacuum oven, Kjeldhal machine, HPLC, Water activity meter, Oxitest oxidation test reactor, UV-Visible spectrophotometer, Muffle furnaces , Raw fiberextractor, Soxhlet extractor, pH meter, Chroma color meter , polarimeter, Brix meter | |
111 | Industrial Development Board (IDB) | Metal | Metal bases (Fe, Cu, Al, Sn, Ti, Zn) | Chemical Composition, Microstructure observation, Rockwell Scales reading, Shore D scale reading, Tensile Strength | Optical Emission Spectrometer, Metallurgical Microscope (Digital), Harness Tester (Rockwell), Hardness Tester, Tensile Testing Machine | |
112 | Industrial Technology Institute (ITI) | Herbal Extracts | essential oil, tea, solvent traces | Analysis of catechins, analysis of coumarin, analysis of alkaloids, Concentrating | HPLC, Rotary evaporator, GCMS | |
113 | Industrial Technology Institute (ITI) | Assays | PCR assays, Bacteria cultures, DNA multiplications, Antioxydent assays, Enzyme inhibitory assays, ORAC assay, antiglycation assay | Fermention, Mamalian cell incubation, Functional analysis, Nucleotide amiplification, Sterilization | CO2 incubator, Gel electro phoresis system, Autoclave, Spectramax Plus 384, PCR machine, Spectrophotometer, Gel documentation system, Ultra Centrifuge, Fermenter, Flourometer, Spectramax Gemini EM | |
114 | Industrial Technology Institute (ITI) | R & D Services | Analytical, Semi-preparative, GC Profiles, Microscopic Identification | Aflatoxin, Material Identification, Composition analysis, Impurity and Adulteration analysis, Linear thermal expansion coefficient, Particle size distribution, Vibration leakage, Thermal Conductivity Test, pH of liquid, thickness, Bulk Density & Water Absorption, dimensions, Transparency, Digestion / irradiation, Material identification, XRD Spectrum & XRD Spectrum with Analysis, Sintering, Ash content & Carbon Black Content, Color Change, Viscosity, Treatment of the ceramic materials, Sieve Residue , Morphology Analysis | Ultra-High Performance Liquid Chromatography (UHPLC), High Performance Liquid Chromatography (HPLC), Gas Chromatography, GC-MS, FTIR, Dialometer, Particle Size Analyzer, Vibration Machine, Portable Thermal Conductivity Meter, Benchtop PH Meter, Digital Micrometer, Analytical Balance, Vernier Caliper, UV-Visible Spectrometer, Microwave Synthesis Lab Station, XRD, Three Zone Tube Furnace, High Temperature Furnace, Viscometer, Sunset Weatherometer, Gradient Klin, Sieve Shaker, High Temperature Furnace, Polarizing Microscope, Dissection microscope, Research microscope | |
115 | Industrial Technology Institute (ITI) | Paper & Packaging | plastic films, sheets, laminated materials, aluminum foil, cardboard, screwing caps, plastic film | water vapor transmission rate, gas permeability, colout control/analysis, visual appearance, leakages, rub resistance, hot tack and heat seal performance | Water Vapour Transmission Rate Tester, Oxygen/Gas Transmission Rate Tester, Colorimeter, Light booth, Thickness Tester, Leak Tester, . Ink Rub Tester, Puncture Resistance , Torque Tester , impact resistance, Environmental chamber, Hot Tack – Heat Seal Tester | |
116 | Industrial Technology Institute (ITI) | Materials | Plastics, rubber, Food, pharmaceutical, dyes, textile, fiber | Thermal Coefficient, Transmittance, Absorption, Spectrum, Composition analysis, Impurity and adulteration analysis, Linear thermal expansion coefficient, Particle size distribution | Differential Dilatometer, Platinum ATR (Attenuated Total Reflectance), FTIR, Dilatometer, Particle Size Analyzer | |
117 | Industrial Technology Institute (ITI) | Residual Analysis | Analysis of Polar Organic Compounds, Elemental Analysis | Analysis of Polar Organic Compounds, Elemental Analysis | LC-MS-MS (QTRAP), ICP-MS, GC-MS, GC-ECD/NPD, GC-ECD/FID, HPLC-DAD/FLD/RI, AAS-FLAME/VGA, AAS-FLAME/VGA | |
118 | Industrial Technology Institute (ITI) | Food & Beverages | Oil, Fertilizer, Fruit, Vegetables, dry food powders, food emulsions, Noodle, Spices, grains, cereal flakes, wet cereals/legumes, wet products, snacks, tea | Cholesterol, Sugar, Caffine content, sordic acid, benzoic acid, Sudan dyes, Vitamins, Nitrogen, Protein, drying, Blending, Oil extraction, Filtering, Grinding, pulp making, slicing, concentrate, food coating, grindings, roasting, stabilizing, Brix value, distillation, olerosin extraction | Gas Chromatograph, HPLC, Kjeldhal Digester Distillation unit, Michel Dryer, Ribbon Blender, Cream Separating Centrifuge, Oil expeller, Filter Press, Kibler Mill, Universal Mill, Pulper, Slicer, Steam Jacketed Kettle, High Pressure Retort, Flavour Coating Drum, Mincer, Spray Dryer, Wet grinder, Flaking Machine, Sieve Shaking Machine, Freez dryer, Roaster Machine, Noodle Machine, Toothe colloidal mill, Refractometer, Microwave etractor, Multipurpose extractor | |
119 | Industrial Technology Institute (ITI) | Water | Fluoride, Chloride, nitrate, nitrite, phosphate, sulfate, elemental analysis | Ion Chromatograph, ICP-MS | ||
120 | Coconut Development Authority | Food | Coconut | Aflatoxin, Poly Aromatic Hydrocarbon, Sugars | High Performance Liquid Chromatography | |
121 | Geological Survey & Mines Bureau | Material Testing | Rocks, minerals, soil and sediment testing | Major elements, trace elements and rare earth elements | X-Ray Fluorescence SpectrometerAtomic absorption SpectrophotometerICP- optical Emission Spectrophotometer UV-Visible spectrometer | |
122 | Geological Survey & Mines Bureau | Water testing | Drinking water, Surface water & Waste water | pH, conductivity, salinity, heavy metals | pH meter, Conductivity meter, Atomic Absorption Spectrophotometer with Hydride Generation and Graphite Furnace, ICP-OES Spectrophotometer | |
123 | Industrial Technology Institute (ITI) | Environmental Chamber |
The environmental test chamber artificially replicates conditions which materials or components might be exposed to. It is also used to accelerate the effects of exposure to the environment. Chamber testing involves exposing packaging materials to various environmental conditions in a controlled setting. Climatic Chamber testing is a broad term used to describe different ways of simulating climate or excessive ambient conditions exposure for a product or a material under laboratory controlled yet accelerated conditions. On the other hand, Thermal Shock testing is used to simulate how materials will react when exposed to changes in extreme climatic conditions, such as going from extremely cold to extremely hot conditions in a very short period of time (usually only few seconds). |
|||
124 | Industrial Technology Institute (ITI) | Thickness Tester | This device measures the thickness of packaging materials such as Plastic Films, Sheeting, Foils, Metal sheets (Foil), etc. up to 2 mm thickness. The material thickness is a measurement which is used during the conception of the packaging product and its specifications. | Thickness Tester | ||
125 | Industrial Technology Institute (ITI) | Colorimeter | The colorimeter is a professional colorimeter designed and produced subject to the relevant national and international standards. The instrument is well designed and features in precision, stability, easy handling, easy to learn and cost-effective. This instrument applies to the color control, color difference control, color difference analysis, sampling testing and online testing for industries such as textile, printing and dyeing, garments, shoes, leather, chemicals, plastics, pigments, paints, inks, metal, photography and toys etc., as well as to the auxiliary color matching during the processes as injection, inking, painting and spraying coating etc. | |||
126 | Industrial Technology Institute (ITI) | Oxygen / Gas Transmission Rate | Gas type, temperature, humidity, pressure and specimen thickness | This test concerns mainly the plastic flexible films and laminates. The Gas permeability is the ability of a barrier material to allow gases (O2, N2, CO2 etc.) to permeate through it in a specific time. Gas permeability may vary with temperature, humidity, pressure and specimen thickness. G2/132 is based on the differential pressure method and is professionally applicable to the determination of gas permeability of film specimens. It is equipped with three diffusion cells, which could generate test results of three equivalent specimens at one operation. | Oxygen / Gas Transmission Rate Tester | |
127 | University of Jaffna | Solar Cell characterization | ||||
128 | University of Jaffna | Solar cell fabrication | ||||
129 | Rajarata University of Sri Lanka | Incubator | heating incubator, low temperature incubator, CO2 incubator | An incubator is a device used to grow and maintain microbiological cultures or cell cultures and maintains optimal temperature, humidity and other conditions such as the CO2 and oxygen content of the atmosphere inside. | heating incubator, low temperature incubator, CO2 incubator | |
130 | Rajarata University of Sri Lanka | Low Temperature Freezer | -25℃ Freezer, -40℃ Freezer, -86℃ Freezer | To store samples | -25℃ Freezer, -40℃ Freezer, -86℃ Freezer | |
131 | Rajarata University of Sri Lanka | Soil Compaction meter | Maximum Soil Compaction | This meter can be used to measure the Maximum compaction value in the soil | Soil Compaction meter | |
132 | Rajarata University of Sri Lanka | Soil Moisture meter | VWC using TDR | Volumetric Water Content (VWC) percentage, EC, Temperature | This meter uses Time Domain Reflectometry for determining Volumetric Water Content in soil. | Soil Moisture meter |
133 | Rajarata University of Sri Lanka | Light meter | Photosynthetically Active Radiation (µmol s -1 m-2 of PAR), Solar Radiation (W m-2 ), Illuminance (lux) | Light measurements can be obtain using radiation sensors. The quantum sensor measures Photosynthetically Active Radiation (µmol s -1 m-2 of PAR), The Pyranometer measures solar radiation (W m-2), and the photometric sensor measures illuminance (lux) | Light meter, Radiation sensors (quantum sensor, Pyranometer, photometric sensor) | |
134 | Rajarata University of Sri Lanka | Particle Size Analysis | Dry sieving, Wet sieving | Particle size distribution | The measurement and graduation of the size of the particles within a material is called particle size analysis. The most common used method of particle size analysis is the sieve analysis. In this method the material is passed through a sieve stack which has different sieve mesh sizes and sieve shaker provides the necessary energy to sieve stack so that material can be filtered through sieves | Sieve Shaker, Test sieves |
135 | National Engineering Research and Development Centre | Vibration Test | Vibration | Widely applicable to the defense, aerospace, communications, electronics, automobiles, household appliances and other industries. The type of equipment used to detect early failure, to simulate the actual condition assessment and structural strength test, and a wide range of applications, applicable wide test results significantly reliable. | ||
136 | National Engineering Research and Development Centre | Tem. / RH Data Logger | Data Logger | Temperature, Humidity | ||
137 | National Engineering Research and Development Centre | Illuminance Calibrator | Illuminance Calibration System | Illuminance | Can be used to calibrate Illuminance Meters (Light Meters, Lux Meters) | Illuminance Meters, Light Meters, Lux Meters |
138 | University of Sri Jayewardenepura | Blood Analysis | Serum | AST,ALT,Glucose,CRP,Cholesterol,Cratinine,Urea,Albumin,Ferritin,TSH | Immuno Analyzer,Biochemical Analyzer | |
139 | National Engineering Research and Development Centre | Shear strength test for soil | Shear strength | |||
140 | National Engineering Research and Development Centre | Water Test Sysyem | Oscillating Tube (IP Test) | |||
141 | National Engineering Research and Development Centre | High Pressure and Temperature Water Jet Chamber | For IP Testing | |||
142 | National Engineering Research and Development Centre | Drip Box | For IP Testing | |||
143 | National Engineering Research and Development Centre | Temperature and Humidity Chamber | For IP Testing | |||
144 | National Engineering Research and Development Centre | Dust Chamber | For IP Testing | |||
145 | National Engineering Research and Development Centre | Battery Tester | Automated Battery Tester | Battery Capacity, Reserve capacity, Cranking Current | Automated Battery Tester | |
146 | National Engineering Research and Development Centre | Convection Oven | Convection Oven- Electric | 60L | Size (W x D x H) (mm)- 400 x 360 x 420 | |
147 | National Engineering Research and Development Centre | Electrical Power Source | Programmable AC Source | Display Voltage, Current, Power, Power Factor, Frequency, Crest Factor | Programmable AC Source | |
148 | National Engineering Research and Development Centre | Bio Fuel Testing | Biomass Testing | Calorific Value | Oxygen Bomb Calorimeter | |
149 | National Engineering Research and Development Centre | Electrical Instruments | Electrical parameters measuring instrument | Voltage, Current, Wattage, Power Factor, Harmonics | Power Analyzer | |
150 | National Engineering Research and Development Centre | Electrical and Thermal Measuring | Electrical and Thermal measuring Instrument | Energy consumption, Temperature performance | Testing unit consisted with temperature sensors, power meters and system software | Testing unit consisted with temperature sensors, power meters and system software |
151 | National Engineering Research and Development Centre | Photometric | Photometric parameters measuring instrument | Luminous flux, Radiant Flux, CCT, CRI, Chromaticity coordinates and Spectral Flux distribution | Measuring Photometric parameters of lamps | Photometric Measurement System (Integrating Sphere, Spectrometer with Software) |
152 | Wayamba University of Sri Lanka | Eliza Plate Washer | Eliza Plate Washer | Washing Purpose | Micro plate washers are laboratory instruments designed to control the procedure of washing experimental samples arranged in plate-based formats. Users load a plate and select a program; micro plate washers then dispense, soak and aspirate liquids from the plate in seconds | |
153 | Wayamba University of Sri Lanka | Eliza Reader | Eliza Reader | Wavelength Range: 190 nm— 1 100 | An Eliza reader is an instrument that is used to read the fluorescent, or chromogenic response o the Eliza in a 96-well plate. The instrument is designed to fit standard 96-well plates, and will provide quantitative information about the extent of the response for each individual well of the plate. This enables up to 96 different conditions to be examined at once. | Computer and Accessories 96 well plate |
154 | Wayamba University of Sri Lanka | Gel Documentation System | Gel Documentation System | UV Exposer 10 narrow bana filters available from 440 to 850nm | Optional epic or transillumination options Interchangeable application pad for U V, blue, green or red fluorescence 10 positions filter wheel | Computer and Accessories |
155 | Wayamba University of Sri Lanka | Freezer -40 C | Freezer | Up to -40 C | freezer series is innovative, reliable, with the latest generation technology solutions for maintaining the medical and scientific cold chain. | |
156 | Wayamba University of Sri Lanka | Freezer -20 C | Freezer | Up to -20 C | freezer series is innovative, reliable, with the latest generation technology solutions for maintaining the medical and scientific cold chain | |
157 | Wayamba University of Sri Lanka | UV-Visible Spectroscopy | Spectrophotometer | Wavelength Range: 300 nm — 800nm | UV-Vis spectroscopy is an analytical technique tha measures the amount o discrete wavelengths o UV, visible or IR light that are absorbed by or transmitted through a sample in comparison to a reference or blank sample. | |
158 | General Sir John Kotelawala Defence University | 3D Printing | CNC, Additive manufacturing | 3D printing refers to processes used to generate a 3D object in which layers of material are successively formed under a computer controlled program to create a physical object. The 3D file source is usually sliced into several layers, each layer generating a set of computer controlled instructions. | ||
159 | General Sir John Kotelawala Defence University | Fluid Composition | Lab Equipment | Concentration, Purity | To test , determineand control the quality and purity of the fluids | |
160 | General Sir John Kotelawala Defence University | Measuring Equipment | Lab Equipment | Dimensions of objects | Capable to measure dimensions of objects accurately with industrial and analytical purposes | |
161 | Sri Lanka Technological Campus (SLTC) - Research University | Soil Mechanics - I | permeability | coefficient of permeability | ||
162 | Central Environmental Authority | Air quality monitoring | noise measurement,fugitive emissions,ambient air quality,indoor air quality monitoring | noise measurement,TSPM,NMVOC,asbestos fibre,PM10,SOx,NOx | ||
163 | Central Environmental Authority | Water quality monitoring | Water and wastewater analysis | pH,EC,Conductivity,turbidity,temperature,Total residual chlorine,COD,BOD,TS,TSS,TDS,O&G,Dissolved phosphates,Total P,Total hardness,chlorides,ammonical N,nitrates,nitrites,alkalinity,sulphides,sulphates,colour,TC&FC,heavy metal | ||
164 | Eastern University, Sri Lanka | Leaf area measurement | leaf area meter | |||
165 | University of Ruhuna | Pharmaceutical equipment | ||||
166 | Eastern University, Sri Lanka | Vacuum filtration | vacuum pump | |||
167 | Eastern University, Sri Lanka | Heating and Stirring Equipment | Hot plate , magnetic stirrer with hot plate, Heating Mantle | |||
168 | Eastern University, Sri Lanka | Safety Equipment | Safety cabinet, bio safety cabinet | |||
169 | Eastern University, Sri Lanka | Crusing of materials | mainly used for crushing various granular farm crops | mill, crusher | ||
170 | Eastern University, Sri Lanka | Measuring Salinity of liquid sample | salinity is the measure of dissolved salts in water | salinity | Refractometer are used to measuring fluids concentration such as sugar content, blood protein content, salinity of water. | refractometer, salinity meter |
171 | Eastern University, Sri Lanka | Grinding the meterials | Meat grinder, Lab grinder | |||
172 | Eastern University, Sri Lanka | Cream separation of Milk | Cream separator | |||
173 | Eastern University, Sri Lanka | Separation of particles suspended in a liquid by centrifugal force | separation fluids based on gravity | Centrifuges, bench top centrifuges, hand centrifuges | ||
174 | Eastern University, Sri Lanka | pH Measurement | pH | pH Meter | ||
175 | Eastern University, Sri Lanka | Concentration of alkali Metals | concentration of metals in a sample | A Flame Photometer is a scientific instrument that is used to analyses the levels of Sodium, Lithium, Potassium, Barium or Calcium in a particular sample. Flame Photometry works by measuring the intensity of light emitted when the element is exposed to a flame. | Flame photometer, flame analyzer | |
176 | Eastern University, Sri Lanka | Viscosity Measurement | viscosity | Viscometers measure the viscosity and flow properties of liquids | Viscometer | |
177 | University of Ruhuna | Engineering Workshop Equipment | Lathe, Milling , Shaping , CNC ,EDM, Wire cut, Plate shearing , Plate bending, Roller bending | Radial drilling, Turning, Taper turning, Thread cutting, Rolling, bending, Shearing | Lathe Machine, Milling Machine, Shaping Machine, CNC wire cut , Plate Shearing Machine, Roller Machine, Sheet Bending Machine | |
178 | Sri Lanka Technological Campus (SLTC) - Research University | Material Testing / Weighing | Weighing Scales | |||
179 | Sri Lanka Technological Campus (SLTC) - Research University | Network Equipment | Access Network | |||
180 | Sri Lanka Technological Campus (SLTC) - Research University | Industrial Equipment | Amplifier | Optical Signal Amplifier | EDFA(Erbiam Droped Fiber Amplifier) | |
181 | Sri Lanka Technological Campus (SLTC) - Research University | Fluid Mechanics | Hydraulic Principles | Flow measurements | Hydraulic bench experiments, Fluid friction apparatus | |
182 | Sri Lanka Technological Campus (SLTC) - Research University | Messuring/Testing Instrument | Signal Analyzer | Signals and Frames | ||
183 | Sri Lanka Technological Campus (SLTC) - Research University | Industrial/Lab Equipment | Signal Generator | Generate Signals | ||
184 | Industrial Technology Institute (ITI) | Spectrometry | Metals | Metal Analysis | The Agilent 7900 ICP-MS (Inductively Coupled Plasma - Mass Spectrometry) is a flexible single quadrupole ICP mass spectrometer that provides the industry’s best matrix tolerance, most effective helium collision mode, lowest detection limits, and widest dynamic range. As a result, you can be confident you are reporting accurate data every time, even at trace levels, whatever your sample types. The 7900 ICP Mass Spec provides the highest performance for demanding commercial and industrial applications, with the flexibility needed for research and advanced analysis such as speciation. High sensitivity and fast acquisition of transient signals – necessary for analysis of single nanoparticles (spICP-MS), single cells, and for laser ablation – give you the edge over the competition. | |
185 | Industrial Technology Institute (ITI) | Microscope | Scanning Electronic Microscope | Microstructure Imaging | The LEO 1420, a high-performance compact SEM, has been specifically designed for the investigation of small to medium samples The LEO 1420, a high-performance compact SEM, has been specifically designed for the investigation of small to medium samples. With a chamber designed for optimum analysis and, and the inclusion of a special cryo port, the LEO 1420 becomes first choice for biological and material applications. | |
186 | Rajarata University of Sri Lanka | Controlled Environment Monitoring | Temperature, Relative Humidity, Light | Incubators, Climate Chambers, Growth Chambers, Controlled Environment Facilities | ||
187 | Sri Lanka Standards Institution | Metals | steel, copper alloys, zinc alloys, aluminium aloys, utensils | chemical composition (C, S, P, Si, Cu, V, Mn, Cr, Ni, Al, N) | analysis of metal composition in all Fe base products (eg.: steel), Cu base / Cu alloys (eg.: Cu wires, medals, buttons, braze utensils), Al Base / Al alloys (Al utensils), Zn base products | Arc/Spark Optic Emission Spectrophotometer (OES) |
188 | Sri Lanka Technological Campus (SLTC) - Research University | Surveying | Measurements | horizontal distances and angles, vertical distances and angles, and slope distances | ||
189 | Sri Lanka Technological Campus (SLTC) - Research University | Bitumen | Transportation Engineering, Testing | |||
190 | Sri Lanka Technological Campus (SLTC) - Research University | Asphalt | Transportation Engineering | |||
191 | Industrial Technology Institute (ITI) | Real Time PCR | Qualitative analysis of gene targets, Quantitative analysis of gene targets, Post PCR melt curve analysis. | |||
192 | Wayamba University of Sri Lanka | Environmental analysis | Atomic Absorption Spectroscopy (AAS) | Concentration of Individual elements in ppm and ppb level | Atomic absorption spectrometry (AAS) is used primarily to determine the concentrations of individual elements in solution. As such, AAS is used in food and beverage, water, clinical research, and pharmaceutical analysis. It is also used in mining operations to determine, metal concentration. | Atomic Absorption Spectroscopy (AAS) |
193 | Wayamba University of Sri Lanka | Thermal property measurement | Thermogravimetric analysis | Determine a material’s thermal stability and its fraction of volatile components by monitoring the weight change that occurs as a sample is heated at a constant rate | Thermogravimetric analysis, or thermal gravimetric analysis (TGA), is a method of determining the overall mass of a sample as a temperature-dependent property. Mass change as a function of temperature is a fundamental property of many materials as they degrade and lose volatile components. | TGA |
194 | Wayamba University of Sri Lanka | Spectroscopy | FTIR | Functional Groups, Chemical Bonds | The fundamental of infrared spectroscopic technology is on atomic vibrations of a molecule that only absorbs specific frequencies and energies of infrared radiation. The molecules could be detected and classified by FTIR because different molecules will have different infrared spectrum. | IRAffinity-1S - FTIR Spectrometers |
195 | Wayamba University of Sri Lanka | Spectroscopy | UV-Visible Spectrometer | Optical absorption or transmittance of liquids, solids and thin-films | UV-Vis spectroscopy is an analytical technique that measures the amount of discrete wavelengths of UV, visible or IR light that are absorbed by or transmitted through a sample in comparison to a reference or blank sample. | shimadzu uv-vis 1800 double-beam spectrophotometer |
196 | Industrial Technology Institute (ITI) | Analysis of small organic molecules | Active pharmaceutical ingredients, Personal care products, Toxins, Pesticide residue | Analysis of Pharmaceuticals, Cosmetics, Pesticide Residues | The 1290 Infinity II LC System is an ultra-high-performance LC that has market-leading sample capacity and is designed for the lowest dispersion for the most challenging ultra-HPLC experiments. The 1290 Infinity II LC system is designed to be both a HPLC and high-end UHPLC system in a single flow path, giving a robust and excellent performance no matter what application is running while seamlessly integrating into existing laboratory environment | |
197 | Veterinary Research Institute | Spectroscopy | Absorption spectroscopy | phosphorus, trypsin inhibitor, tannin, phytate | Ultraviolet-visible (UV) visible spectrophotometer uses a light source to illuminate a sample with light across the UV to the visible wavelength range to quantify the reaction to measure the parameters. | Ultraviolet-visible (UV) visible spectrophotometer |
198 | Industrial Technology Institute (ITI) | Nitrogen Analyzer | Food, Fertilizer | Nitrogen Analysis, Protein Analysis | The UDK 149 is a convenient and reliable solution for safe, semi-automated distillations. The perfect distiller for laboratories looking for precise and reproducible results of Kjeldahl nitrogen TKN, proteins, ammoniacal nitrogen, nitrate nitrogen, TVBN, sulfites, phenols, volatile acids, cyanides, and alcohol content | |
199 | Industrial Technology Institute (ITI) | Nitrogen Analyzer | Food, Fertilizer | Nitrogen Analysis, Protein Analysis | The UDK 149 is a convenient and reliable solution for safe, semi-automated distillations. The perfect distiller for laboratories looking for precise and reproducible results of Kjeldahl nitrogen TKN, proteins, ammoniacal nitrogen, nitrate nitrogen, TVBN, sulfites, phenols, volatile acids, cyanides, and alcohol content | Scrubber |
200 | Industrial Technology Institute (ITI) | Material Identification | Graphite, Clay, Quartz | Crystalline Material Identification | The Ultima IV represents the state-of-the-art in multipurpose X-ray diffraction (XRD) systems. Incorporating Rigaku's patented cross beam optics (CBO) technology for permanently mounted, permanently aligned and user-selectable parallel and focusing geometries, the Ultima IV X-ray diffractometer can perform many different measurements. | |
201 | Industrial Technology Institute (ITI) | Material Characterization | Polymer, Rubber | Transmittance, Absorption. | Fourier-Transformed InfraRed (FTIR) spectroscopy is a well-defined technique for material characterization. Because compounds are arranged in a unique combination of atoms, no two compounds produce the exact same InfraRed (IR) spectrum. Therefore, IR spectroscopy can result in a positive identification (qualitative analysis) of functional groups and combinations of groups in organic molecules. Additionally, the intensity of the peaks measured on these unique spectra are directly correlated to the amount of that material present within the sample. The Center’s Bruker Tenor 27 has several reconfigurable accessories that allow for a variety of sample measurements. Solids, liquids, and films can be measured using the diamond lens Attenuated Total Reflectance (ATR) module | |
202 | The Open University of Sri Lanka | Aerodynamics | Testing, Wind-tunnel | Wind-tunnel Testing | ||
203 | Sabaragamuwa University of Sri Lanka | Sample Ashing | ||||
204 | Sabaragamuwa University of Sri Lanka | Sample Sterilization | ||||
205 | Sabaragamuwa University of Sri Lanka | Purified Water Generator | ||||
206 | Sabaragamuwa University of Sri Lanka | Solvent Evaporator under Control Conditions | ||||
207 | Sabaragamuwa University of Sri Lanka | Sample Drying Under Vacuum | ||||
208 | Sabaragamuwa University of Sri Lanka | Chromatographic Analysis | ||||
209 | Wayamba University of Sri Lanka | X ray Diffractometer | Crystal Structure, Crystalline phases, Chemical Composition information | Crystal Structures, Lattice Parameters, Atomic arrangement, Crystallite size | X Ray Diffraction Analysis is important to investigate crystalline material structure as well as atomic arrangement, crystallite size and imperfections. | Rigaku Ultima IV XRD |
210 | Industrial Technology Institute (ITI) | Material Characterization | Ceramics, Glass, Clay | Thermal coefficient of expansion | For highest measurement accuracy, DIL 802 provides a truly differential measurement. Measuring only the difference between the sample and the reference specimen with the same, single LVDT-sensor, the True Differential design negates the influence of measurement system expansion on the sample measurement. This measurement design is of particular benefit for dynamic temperature programs such as those employed in Rate-Controlled-Sintering (RCS) and for measurements of samples with small thermal expansion. The DIL 802 is designed for measurements under vacuum or inert gas while the DIL 802L is designed for measurements under air. | |
211 | Sabaragamuwa University of Sri Lanka | Electronic Undergraduate Practical | ||||
212 | Sabaragamuwa University of Sri Lanka | Mass Measurement | ||||
213 | Sabaragamuwa University of Sri Lanka | Computer based Physics Practical | ||||
214 | Sabaragamuwa University of Sri Lanka | Geophysics | ||||
215 | Sabaragamuwa University of Sri Lanka | Charge Determination | ||||
216 | Sabaragamuwa University of Sri Lanka | FTIR Analysis | ||||
217 | Sabaragamuwa University of Sri Lanka | Spectroscopic Analysis | ||||
218 | Sri Lanka Technological Campus (SLTC) - Research University | Soil Mechanics | Soil Strength Properties | Direct Shear Strength, Consolidation rate, Triaxial strength | Direct Shear Apparatus, Consolidation Apparatus, Triaxial Test | |
219 | Sri Lanka Technological Campus (SLTC) - Research University | Column Testing | Buckling of Struts | Universal Frame and Stand - Buckling tester | ||
220 | Sri Lanka Technological Campus (SLTC) - Research University | Beam Testing - Model | Deflection, Simply supported/Cantilever/Continuous Beam | Deflection | ||
221 | Sri Lanka Technological Campus (SLTC) - Research University | Laboratory Oven | Laboratory Drying Ovens, Sample Preparation | |||
222 | Sri Lanka Technological Campus (SLTC) - Research University | Material Testing / Impact | Strength Properties, Materials, Testing | Impact Testing | Pendulum Impact Tester | |
223 | Veterinary Research Institute | sterilization | Autoclaving | Autoclave is a machine that uses steam under pressure to kill harmful pathogens including spores on items that are placed inside a pressure vessel. | Autoclave | |
224 | Sri Lanka Technological Campus (SLTC) - Research University | Material Testing / Hardness | Physical Properties, Materials, Testing | Vickers Hardness, Brinell Hardness, Rockwell Hardness | Hardness Tester | |
225 | Sri Lanka Technological Campus (SLTC) - Research University | Material Testing / UMT | Physical Properties, Materials, Testing | Tensile testing, Compression testing, Stress-Strain Diagrams | Universal Material Tester | |
226 | University of Vocational Technology | Food | Food, Agriculture ,Bio Chemistry, Pharmaceutical | Drying of heat sensitive material, Dehydration, Protein , Fat | Vacuum Drying Oven Dehydrator Kjeldahl Apparatus Soxlet Apparatus | |
227 | Veterinary Research Institute | Microscopy | Cell culture | Cells and cell components | Phase contrast microscope is a light microscope that enhances the contrast of image of transparent and colourless specimens. It enables visualization of cells and cell components that would be difficult to see using an ordinary light microscope | Phase contrast microscope |
228 | Veterinary Research Institute | Tissue processing | Histopathology | cellular changes | Provides facilities to complete embedding of tissue samples and preparation of tissue blocks easily and rapidly. | Embedding module, paraffin dispenser, thermal console |
229 | National Institute of Fundamental Studies | chemistry | ||||
230 | University of Jaffna | Ceramic processing | ||||
231 | Industrial Technology Institute (ITI) | Organic Residues | Pesticides, Mycotoxins, Veterinary antibiotic residues, Food Adulterants, food allergens, Solvent residues, Industrial Contaminants | Aflatoxins, Pesticides, Histamine, DCD, Melamine, PAHs, PCBs, Phthalates | The 7000D Triple Quadrupole GC/MS is the latest version of the most successful GC/MS/MS in history. The 7000D is now even easier to use and more efficient than ever, due to its new Dynamic MRM (dMRM) mode of acquisition. Coupled with the 9000 GC, the 7000D MS works in perfect harmony to enhance productivity, save resources and alert operators about pending maintenance | |
232 | Industrial Technology Institute (ITI) | Organic Residues | Pesticides, Mycotoxins, Veterinary antibiotic residues, Food Adulterants, food allergens, Solvent residues, Industrial Contaminants | Aflatoxins, Pesticides, Histamine, DCD, Melamine, PAHs, PCBs, Phthalates | Known as the LC-MS/MS workhorse, this is the intelligently re-engineered design of the 4000 QTRAP Platform, and sets a new benchmark for robust quantitation and library searching. The system is ideal for laboratories requiring ultimate robustness, ruggedness, and reliability for high-throughput screening of many compounds in many samples every day | |
233 | Industrial Technology Institute (ITI) | Pharmaceuticals | Absorbance, Transmitted spectrum | Platinum ATR (Attenuated Total Reflectance) | ||
234 | Industrial Technology Institute (ITI) | Pharmaceuticals | Cosmetics, Colognes, Sanitizers, Pharmaceutical preparations, Pharmaceutical Raw Materials | Solvents, Assays, Fatty acids | The TRACE 1300 Series GC is a fast, easy to use and versatile GC system which delivers extremely high levels of laboratory productivity. Instant connect-FID (Flame Ionization Detector) gives highest sensitivity and wide dynamic range with rapid acquisition speed making it ideal for fast GC application | Head Space, FID (Flame Ionization Detector) |
235 | National Institute of Fundamental Studies | Chromatography | The Gas Chromatography systems is with 7693Aauto injector, Microelectron capture detector with EPC and single FPD plus. The column is used to analyse short chain and long chain fatty acids. | |||
236 | National Institute of Fundamental Studies | Molecular Biology and Biotechnology | PCR amplification, Melt Curve analysis | |||
237 | National Institute of Fundamental Studies | Earth Science | Magnetic Field, GIS | total magnetic field, magnetic field gradient, Precicon positioning | ||
238 | National Institute of Fundamental Studies | Material Science | Vaccuum tube furnace, Spin coater | |||
239 | National Institute of Fundamental Studies | Solar cells | Photo- voltaic characteristics, photosensitivity | |||
240 | National Institute of Fundamental Studies | Thermodynamics | conducting thermodynamic experiments, determination of the effect of temperature on adsorption of pollutants on adsorbent materials | |||
241 | National Institute of Fundamental Studies | Water Quality | wastewater, drinking water, | Aluminum, Ammonia, Bromine, Chlorine, total Clorine, detergents, heavy metals, COD, hardness, | LED- sources portable colorimeter that measures at wavelengths of 420,520,560,610 nm | |
242 | National Institute of Fundamental Studies | Microbiology | Soil microbiology | This is used for isolation and handling of anaerobic microorganisms | ||
243 | National Institute of Fundamental Studies | Surface charge measurements | Can obtain surface charge measurements in solids, membranes , nanotubes and thin films | |||
244 | Veterinary Research Institute | Freeze drying | Bacterial cultures | It is designed to work with a wide variety of drying accessories; flasks, vials, and ampules and currently used for the production of freeze dried veterinary vaccines, yoghurt and curd starter cultures and to preserve bacterial cultures. | Spark tester (for vacuum testing of the product) | |
245 | Institute of indigenous Medicine | Herbal Pharmaceutical | Cosmetics, Food supplementary | wavelength, absorbance of particular wavelength, spectrum | The CAMAG TLC SCANNER 4 is designed for densitometric measurement of thin-layer chromatograms and other objects upto 200x200 mm in size. While the Scanner 4 performs the actual densitometric measurement, data is processed by the CAMAG vision CATS/win CATS Planar Chromatography Manager running on a connected computer. | UV lamp, TLC Chambers, Orbital shaker, rotary evaporator |
246 | The Open University of Sri Lanka | Metrology | Measurements, Computer aided measurement, Manufacturing | |||
247 | The Open University of Sri Lanka | Automobile | Testing, Emission | |||
248 | The Open University of Sri Lanka | Material Testing | Metal | |||
249 | The Open University of Sri Lanka | Machining equipment | CNC Machine, Unmanned machining operations, Manufacturing | CNC Lathe, CNC Milling | ||
250 | Institute of indigenous Medicine | Herbal Pharmaceutical | Cosmetics, Food supplementary, Essential oils | pH , Ion , mV (Mili Volt) | The pH 510 meter is capable of measuring pH/ORP with Temperature; while the Ion 700-meter measures Ion Concentration/pH/ORP with temperature. It is equipped with a large, customized LCD (Liquid Crystal Display) with simultaneous display of the measured values for easy reading. It is most ideal for routine pH/Ion Concentration measurement in indoor applications. | |
251 | University of Ruhuna | Metallography and Material analysis | Microscopy, Furnace, smart thermography, Hardness | Material testing, Optical imaging | Microscope, Furnace, Thermal imager , Hardness tester | |
252 | Rajarata University of Sri Lanka | Data loggers | Designed for use in researches | Cloud - based data delivery | The ZL6 data logger uses to deliver near-real-time data wherever and whenever you need it, downloading data in the field and easy to distribute and share them. | Data logger ZL6 (Maxim Integrated) |
253 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Absorbance | Absorbance - Surface Water, Groundwater, Drinking Water Sources, Domestic Sewage. | Absorbance and Transmittance | The Ultraviolet Spectrophotometer (UV-1800) can be used to measure the absorbance and transmittance at a single or multiple wavelengths, obtain sample spectra, calculate the concentration of unknown samples through calibration curves, and analyze DNA and proteins. | AoYo - Ultraviolet spectrometry (UV - 1800) |
254 | National Science Foundation | Pharmaceutical | ||||
255 | University of Vavuniya | Incubators are used for the growth of microorganisms in many fields. | To provide a controlled, contaminant-free environment for safe and reliable work with cell and tissue cultures by regulating conditions such as temperature, humidity, and CO2. | Four factors are of major importance in incubating : temperature, humidity, ventilation, and turning. | Incubator, an insulated enclosure in which temperature, humidity, and other environmental conditions can be regulated at levels optimal for growth, hatching, or reproduction. | Incubator, Thermo Fisher Scientific Heratherm IMH -100S |
256 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Inorganic - Multi Elements | Multi Elements- Surface Water, Groundwater, Drinking Water Sources, Domestic Sewage. | Iron(Fe), Boron(B), Molybdenum(Mo), Aluminium(Al), Chromium(Cr), Copper(Cu), Zinc(Zn), Nickel(Ni), Lead(Pb), Selenium(Se), Manganese(Mn), Arsenic(As), Cadmium(Cd), Antimony(Sb), Uranium(U) | Inductively coupled plasma mass spectrometry (ICP-MS) is a type of mass spectrometry that uses an inductively coupled plasma to ionize the sample. It atomizes the sample and creates atomic and small polyatomic ions, which are then detected. | Thermo Fisher - Inductively coupled plasma mass spectrometry |
257 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Inorganic ( Heavy Meatals) | Heavy Metal- Surface Water, Groundwater, Drinking Water Sources, Domestic Sewage. | Arsenic, Mercury | AFS is an analytical method used to determine the concentration of elements in samples. The sample is converted to gaseous atoms, and the element of interest is excited to a higher electronic energy level by a light source. | Beifen Ruili - Atomic Fluorescence Spectroscopy (AFS) |
258 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Inoganic Compounds ( Anions) | Anions- Surface Water, Groundwater, Drinking Water Sources, Domestic Sewage. | Fluoride, Chloride, Nitrate, Sulphate, Phosphate, Bromide | Ion chromatography, a form of liquid chromatography, measures concentrations of ionic species by separating them based on their interaction with a resin. Ionic species separate differently depending on species type and size. | Shine- Ion Chromatograph |
259 | University of Vavuniya | Separates the object to be heated from all byproducts of combustion from the heat source. | Allow rapid high-temperature heating, recovery, and cooling in self-contained, energy-efficient cabinet. | - | Muffle furnace refers to a type of jacketed enclosure that is used to heat a material to significantly high temperatures while keeping it contained and fully isolated from external contaminants, chemicals or substances. | Muffle Furnace,HOBERSAL,Model HD -230 |
260 | University of Vavuniya | Based on the measurement of the emitted light intensity when a metal is introduced into the flame. | The compounds of the alkali and alkaline earth metals (Group II) dissociate into atoms when introduced into the flame. Some of these atoms further get excited to even higher levels. But these atoms are not stable at higher levels. | A Flame Photometer is a scientific instrument that is used to analyses the levels of Sodium, Lithium, Potassium, Barium or Calcium in a particular sample. Flame Photometry works by measuring the intensity of light emitted when the element is exposed to a flame. | The principle of flame photometer is based on the measurement of the emitted light intensity when a metal is introduced into the flame. The wavelength of the colour gives information about the element and the colour of the flame gives information about the amount of the element present in the sample. | Flame Photometer, Jenway,PFP7 |
261 | University of Vavuniya | It is an optical instrument that measures the intensity of light in relation to the wavelength | Useful to measure the absorbance, reflectance, and transmission of light by gases, liquids, and solids | Spectrophotometers measure absorbance (A) and transmittance (T). The intensity of light (I0) measures photons per second. | Widely used in various disciplines such as physics, molecular biology, chemistry and biochemistry. Applications for specs include measurement of substance concentration such as protein, DNA or RNA, growth of bacterial cells, and enzymatic reactions. Important features to look for in spectrophotometer are broad dynamic range, sample volume capability and lamp type and lifetime. | SPECTROPHOTOMETER,JENWAY,MODEL 6305 |
262 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Volatile Organic Compounds | Pesticides, Disinfection byproducts, Industrial chemicals etc. | Volatile Organic Compounds | Gas chromatography (GC) is a common analytical technique used to separate and analyze volatile and semi-volatile compounds in a mixture. GC is a popular analytical technique as it combines exceptional resolving power with speed and sensitivity. | Thermo Fisher Gas Chromatograph-mass spectrometer; Thermo Fisher Gas Chrmatograph-tandem quadropole mass spectrometer; Shimadzu Gas Chromatograph coupled with FID/ECD Detectors; Thermo Fisher Gas Chromatograph FID Detector |
263 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Carbon, Hydrogen, Nitrogen Element Analysis | Soil, Sludge, Charcol, poultry feed, etc | Carbon, Hydrogen, Nitrogen | This elemental analyzer stands for highest performance and versatility in elemental analysis. The vario EL cube is designed for simultaneous carbon, hydrogen, nitrogen, and sulfur analysis. Vario EL cube will perfectly adjust to all your analytical needs in elemental analysis with highest precision and accuracy. Thanks to its low-maintenance design, the vario EL cube is optimized for unattended 24/7 operation and highest system uptime. | Elementar - vario EL cube |
264 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Total Organic Carbon (Purified Samples EC<5μS/cm) | Pharmaceutical Water, Ultrapure Water, Semiconductor Water | Total Organic Carbon | The HTY-DI1500 laboratory TOC Analyzer is designed to determinate the TOC levels of purified water and Ultra-purified water. It uses UV lamp oxidation technology for accurate, dependable operation with minimal maintenance. The analysis is made by the software installed on computer, it is easy to operate and in compliance with the GMP and 21CFR PART 11 requirements. | Tailin-HTY-DI1500-OL |
265 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Non-Volatile Organic Compounds | Pesticides,Personal Care Products,Persistent Organic Pollutants, Pharmaceutical Chemicals, Industrial Waste etc. | Non-Volatile Organic Compounds | High performance liquid chromatography or commonly known as HPLC is an analytical technique used to separate, identify or quantify each component in a mixture. The mixture is separated using the basic principle of column chromatography and then identified and quantified by spectroscopy. | Thermo Fisher HPLC coupled with UV/FLD detectors ; Thermo Fisher UHPLC Tandrum quadrupole mass spectrometer |
266 | South Eastern University of Sri Lanka | Electronic Instruments | ||||
267 | Rajarata University of Sri Lanka | Growth Chamber | Designed for use in science, research, laboratories. | Temperature range 0°C - +60°C , Humidity Range 50% - 95% RH | Only for Stored Product Insects. | Growth Chamber (HiPoint FH-1200) |
268 | South Eastern University of Sri Lanka | Electrical Instuments | Current, Voltage, Frequency, Power | |||
269 | Gampaha Wickramarachchi University of Indigenous Medicine | High-temperature testing applications | ||||
270 | Rajarata University of Sri Lanka | Pressure Bombs | Scholander Type Pressure Bombs | Plant Water Potential | The Pressure Chamber Instrument or Cavitation Chamber must only be used for the purpose it was intended; that intended purpose is to pres-surize plant samples in order to measure xylem water potential, or Plant moisture stress (PMS). | Pressure Chamber |
271 | Rajarata University of Sri Lanka | Climate Chamber | Designed for use in science, research, laboratories and industrial applications. | Temperature control between 10º and 60º and Humidity control between 10% and 80% | Climate Chamber stand out due to their unparalleled temperature and humidity homogeneity for longterm stable ambient conditions. specially designed for testing pharmaceutical products , and similar global standards for stability tests of cosmetics and food. | Climate chamber (Memmert ICH110) |
272 | Rajarata University of Sri Lanka | Unmanned Arial Vehicles | Drones | Video: Full HD 1080p, Photo: 14MP, 4 sensors to capture different wavelengths, RGB camera for visible mapping | Parrot Bluegrass is a multipurpose quadcopter designed for agriculture that helps farmers improve their ROI, using its 2 embedded cameras; video camera and multispectral sensor. With its front Full HD video camera | Drone (Parrot Bluegrass) |
273 | Tea Research Institute of Sri Lanka | Tea (S) | Flowers, Seeds, Seedlings, Seedling roots | Pollen viability, Germination | Florescence Microscope, Microscope and Height-performance FULL HDMI camera, Inverted Microscope & Leika DC-160 camera, Inverted Microscope | |
274 | National Institute of Post Harvest Management (NIPHM) | Food & plant | Plant materials, Microbes | Bacteria, Fungus, Plant materials, flours, Liquids | Identification and process images of micro environments of plant, food, flours, and liquids | Microscope |
275 | National Science Foundation | NSF_TEST_CAT | test | test | test | test |
276 | National Institute of Post Harvest Management (NIPHM) | Fruit & Vegetable | Heavy metal analysis | Sample digestion | Use for sample digestion | AAS |
277 | National Institute of Post Harvest Management (NIPHM) | Freeze Drying of food samples | Sample preparation for analysis | Sample preparation | Processed foods, fruits and vegetables can dehydrate at low temperature for preparation of samples for high sensitive analysis using HPLC, GCMS | Heat pump dryer |
278 | Tea Research Institute of Sri Lanka | Equipment | Glass ware, Medium, Material | Sterilize | Autoclave | |
279 | Tea Research Institute of Sri Lanka | Fertilizer | Organic, Inorganic | Total Nitrogen, Phosphorus, Biuret Test, Potassium, Sodium, Magnesium, Calcium | Kjeldahl method | Nitrogen distillation unit, Digestion unit, Spectrophotometer, Flame photometer, AAS |
280 | Tea Research Institute of Sri Lanka | Tea leaves | Fresh, Freeze dried | Total Nitrogen, Phosphorus, Sulfur, Boron, Potassium, Magnesium, Calcium, Ferrous, Copper, Manganese, Zinc, Caffeine, Anthocyanin, DNA & RNA quality & Quantity | Nitrogen distillation unit, Digestion unit , Muffle Furnace, Flame photometer, AAS, Leaf area meter, HPLC, Spetrophotometer, PCR, Qubit Fluorometer, Gel Document Unit, Dual Gel Vertical Electrophoresis Unit | |
281 | Tea Research Institute of Sri Lanka | Soils & Plants | pH, EC, Phosphorus, Sulfur, Boron, Potassium, Sodium, Magnesium, Calcium, Ferrous, Copper, Manganese, Zinc, Total Nitrogen, Available Nitrogen (Ammonium Nitrogen/ Nitrate Nitrogen), Metals, Heavy metals & Other Element | pH meter, pH/EC meter, Spectrophotometer, Flame photometer, AAS, Nitrogen distillation unit , Digestion unit, ICP-OES | ||
282 | National Institute of Post Harvest Management (NIPHM) | Chemical composition | Phytochemical compounds, Ethephon, Pesticide residues | Ethephon, Pesticide residues, profile analysis | The GCMS in the analytical laboratory can be used to analyze residues, phytochemicals, and chemical composition profile | HPLC/MS |
283 | National Institute of Post Harvest Management (NIPHM) | Gas composition | Ethylene, Carbon Dioxide, Oxygen, Carbon Monoxide | CO2, O2, N2, CH4, CO, C2H4, C2H4, C2H6, C2H2, H2S, C3H8 | The instrument can be used to analyzed a gas composition when fruits ripening, other deteriorations of fruits and vegetables, and grains | Gas analyzer |
284 | Tea Research Institute of Sri Lanka | Made tea | Black tea, Green tea, Instant tea | Total Polyphenol, Total Amino acid, Total Catechin, Caffeine, TF-TR, Glucose, Fructose, SucroseTotal Ash, Water insoluble ash, Acid soluble ash, Alkalinity of water soluble ash, Crude fiber | ISO Standards | Spectrophotometer, HPLC, FT-NIR, Oven, Muffle furnace |
285 | National Institute of Post Harvest Management (NIPHM) | Food | Phytochemical compounds, Phenolic compounds, Vitamins, Antioxidants | Vit A, Vit C, Vit D, Sucrose, Fructose, Glucose, Capsaicin | Analysis of food | UHPLC, GCMS , Freeze dryer |
286 | Rajarata University of Sri Lanka | Metal Shaping | Metal | NA | can cut curves , angles etc. Can generate straight and flat surfaces for internal splines, Making gear teeth | |
287 | Rajarata University of Sri Lanka | metal removal by milling process | Milling, Vertical Milling, Horizontal Milling, Engineering workshop, metal, alloys, wood, polymer | A milling machine having a table fitted with all motions and a dividing head with change gears so that it can perform any type of milling operation | ||
288 | Rajarata University of Sri Lanka | surface grinding | metal, alloys, polymer | A tool used to provide precision ground surfaces either to a critical size or for the surface finish | ||
289 | Rajarata University of Sri Lanka | Material Analysis | polymer | NA | Moisture Loss, loss of solvent decomposition for biomass oxidation | |
290 | Rajarata University of Sri Lanka | Drilling Machine | Metal ,wood, polymer | NA | A drilling machine with drill spindle in a tool head and saddle that are movable along a projecting arm which it self can | |
291 | Rajarata University of Sri Lanka | CNC laser cutter | Metal cutter, wood, polymer, cardboard, hard board | NA | Super hot laser is condensed down to a narrow beam and is used to cut through metals of various thicknesses | |
292 | Rajarata University of Sri Lanka | CNC lathe | Metal cutting | NA | CNC machines are available for milling, and different type of surface finishing | |
293 | Rajarata University of Sri Lanka | Material Surface Analysis | metal, alloys, polymer | Analytical technique used to Determine a materials thermal stability by measuring mass changes in response to increase of temperature or time . | ||
294 | Rajarata University of Sri Lanka | Gas Analyzer | Portable Photosynthesis system | Portable photosynthesis systems for gas exchange and chlorophyll fluorescence measurements | Measurement of chlorophyll fluorescence and gas exchange over the same leaf area, photosynthesis systems for learning, teaching, and performing high-level plant physiology research. | LI-6400XTR Portable Photosynthesis System |
295 | Rajarata University of Sri Lanka | CNC lathe | Metal cutting | NA | ||
296 | Rajarata University of Sri Lanka | Laboratory Analytical | Analytical technique used to determine a materials thermal stability by measuring mass changes in response to increase of temperature or time. | |||
297 | Rajarata University of Sri Lanka | Drill Machine | metal,wood | A drill machine with drill spindle in a tool head and saddle that are movable along a projecting arm which it self can | ||
298 | Rajarata University of Sri Lanka | Microbial Fermenter with Crossflow System | Biostat® A Sartoflow Smart Crossflow System | The SARTOFLOW® Smart is a modular and flexible small scale benchtop crossflow system optimized for ultrafiltration and diafiltration applications used in many downstream processes, such as purification of vaccines, monoclonal antibodies and recombinant proteins. The system is suitable for use in laboratory environments for process development and clinical trials as well as for cGMP environments. | The Sartoflow® Smart is a modular and flexible small scale benchtop crossflow system optimized for ultrafiltration and diafiltration applications used in many downstream processes, such as purification of vaccines, monoclonal antibodies and recombinant proteins. | |
299 | Rajarata University of Sri Lanka | Plant Cell Culture Bioreactor | Cell Culture Bioreactor Biostat® A | Microbial culture, growth of bacteria, yeast, and fungi , Cell culture , growth of animal, insect, and plant cells , Transition from shake or tissue culture flasks , Small-scale protein expression , For education and research | The BIOSTAT®A plus is a compact, autoclavable fermentor/bioreactor system specially designed for educational use and preliminary or investigational R&D applications The BIOSTAT®A plus is a compact, autoclavable fermentor/bioreactor system specially designed for educational use and preliminary or investigational R&D applications. The single housing design concept with integrated measurement and control hardware, pumps, temperature, gassing and motor systems, saves valuable laboratory bench space. The application-driven, configured packages for microbial and cell culture include everything needed for to get started immediately. The BIOSTAT®A plus is available with 1 L, 2 L, or 5 L working volume single wall culture vessel. Just select the size that meets your needs today – it can be interchanged for another vessel, if needed. Each system also includes a powerful Notebook PC with local control software, as well as our MFCS/DA software package for simultaneous control and data collection. | |
300 | Rajarata University of Sri Lanka | Gel Documentation System | Imager System | UV lights / intensity , white lights | Equipment widely used in molecular biology laboratories for the imaging and documentation of nucleic acid and protein suspended within polyacrylamide or agarose gels. | Gel Documentation System (SmartView Pro 1100 Imager System, UVCI-1100) |
301 | Rajarata University of Sri Lanka | Chlorophyll Meter | SPAD Meter | Measure - chlorophyll content, SPAD value | This device that is widely used for the rapid, accurate and non-destructive measurement of leaf chlorophyll concentrations. | SPAD 502 Plus Chlorophyll Meter |
302 | Rajarata University of Sri Lanka | Micro Manipulator | Trinocular Inverted Microscope | visualized biological cultures or specimens and live cells. | Inverted microscopes are suited for observation of biological cultures or specimens within well plates, petri dishes, slides and vials. | inverted microscope (Vanguard 1400INi ) |
303 | Rajarata University of Sri Lanka | Light Meter | Measure - illuminance in the field | Lux, Foot-Candle | This meter is a precision instrument used to measure illuminance (lux, foot-candle) in the field. | Brannan - Light Meter |
304 | Rajarata University of Sri Lanka | Multi- Functional environment meter | Measure - HUMIDITY & TEMPERATURE | Humidity 0 to 100%RH , Temperature -35 to 100°C -31 to 212°F | The Humidity & Temperature Meter is designed with a high accuracy temperature & humidity sensor, providing high accuracy, fast response and stable readings. This meter can be used for a variety of practical applications for professional and home use, for example. monitoring and collecting data of environmental temperature and humidity in factories, schools. offices, airports, home, etc., | Professional Standard Environmental Meter - Brannan Thermometer & Humidity Meter 13/463/0 |
305 | Rajarata University of Sri Lanka | GRAIN MOISTURE METER | APPLICATIONS & MEASURING RANGES OF GRAINS | Moisture percentage of - Paddy, Rice, Soya beans, Barley, Wheat, Maize | This meter checks the moisture content in grains and seeds accurately and quickly,it is compact, easy to use and the moisture measurement readings are instant.It helps decide the ideal time to harvest the crops and helps keep a constantmoisture content of the grains and seeds. | GRAIN MOISTURE METER / G-WON ( GMK-303A) |
306 | Rajarata University of Sri Lanka | Thermal Cyclers / PCR | MyCycler Thermal Cycler | 96-well PCR system with a gradient feature used for gene amplification , Program protocols with as many as 9 cycles with 9 steps each and repeats up to 99 times per cycle. | PCR system with a gradient feature used for gene amplification. This compact thermal cycler features intuitive programming of temperatures, times, and protocols with ready-made templates for ease of viewing, editing, and running protocols. | Biorad MyCycler Thermal Cycler / PCR |
307 | Rajarata University of Sri Lanka | UV - Spectrophotometer | That can measure the intensity of a light beam at different wavelengths. | Wavelength Range: 190 nm – 1100 nm , Spectral Bandwidth 1.0 nm | Used extensively for qualitative and quantitative analysis in such fields as pharmaceutical inspection, clinical analysis, petro-chemistry laboratories, chemistry and biochemistry laboratories, DNA/RNA analysis. | UV-VIS Spectrophotometer (Model - Labomed UVD2950) |
308 | Department of Agriculture | Product texture | Grinding | To Sample grinding | Grinder | |
309 | Department of Agriculture | chemical properties | Microwave digestion | Macro and micro nutrients | Microwave digester | |
310 | Department of Agriculture | Elements in solution | To measure concentrations of macro and micro elements | Flame atomic absorption spectrometer, Graphite atomic absorption | ||
311 | Department of Agriculture | water | water purification | To measure water purification | water purification unit | |
312 | Department of Agriculture | chemical properties | Pottasium in soil,palnt,fertilizer and organic manure | To measure pottasium in soil | Flame photometer | |
313 | Department of Agriculture | UV-Visible spectroscopy | spectrophotometer | soil , plant ,organic manure and fertilizer | To measure soil Phosphorous | spectrophotometer |
314 | Department of Agriculture | Water conductivity | Electrical conductivity | soil EC | To measure EC of soil and organic manure | conductivity meter |
315 | Department of Agriculture | Water pH | Soil pH | pH | To measure pH | pH meter |
316 | Department of Agriculture | weight | soil weight | To weighing soils | Analytical balance, top pan balance | |
317 | Coconut Research Institute of Sri Lanka | Pathogen Detection | Amplifies specific region of a DNA Strand | Amplified DNA product use for the Gel Electrophoresis | Polymerase Chain Reaction technique allows specific region of a DNA to be amplified through the Thermal-cycler. Any kind of extracted DNA can be used as the sample and primers designed accordingly to the region to be amplified, should be provided in the reaction mixture. Amplified PCR products are used for the Electrophoresis. | TAKARA PCR Thermal Cycler, TECHNE TC-5000 PCR Thermal Cycler |
318 | Uva Wellassa University | Nitrogen and Protein Analysis | Nitrogen and Protein contents in Chemical Substances | Nitrogen, Protein | The Kjeldahl method is an analytical method for the quantitative determination of nitrogen in chemical substances. This is a standard method for estimating the protein content in foods, feed, beverages, and many other samples. The Kjeldahl method involves three main steps, i.e. digestion of organic nitrogen, the distillation of ammonia and titrations to determine nitrogen content in samples. The Kjeldahl method is also used to measure nitrogen in organic and inorganic samples in the chemical industry, the pharmaceutical industry and in environmental samples. For example, nitrogen determination in wastewaters and soil samples. | Kjeldahl apparatus |
319 | Sri Lanka Standards Institution | Porcelain Tableware | Porcelain Tableware, Ceramicware, Glass Ceramicware, Glass dinnerware | Test for release Lead and Cadmium | Atomic Absorption Spectro[photometer | |
320 | Sri Lanka Standards Institution | Fertilizer | Fertilizer and Fertilizer mixtures | Total Nitrigen, Ammnical Nitrogen, Total Phosphorus, Water Soluble Phosphorus, Citric acid Soluible Phosphorus, Total Pottasium, Water Soluble Potassium, Calcium, Magnisium, Biuret, Moisture, Trace metals | UV-Spectrophotometer, Atomic Absorbtion Spectrophotometer, ICP-MS | |
321 | Sri Lanka Standards Institution | Water | Bottled Drinking Water, Natural Mineral Water, Waste Water | Odour, Taste, pH, Sulphate, Suspended Solids, Total Dissolved Solids, Turbidity, Magnesium, Nitrates, Total Phoshorous, Chloride, Electrical Conductivity, Hardness, Total Alkalinity, Free Ammnonia, Albuminoid ammonia, Calsium, COD, Free residual Chlorine, Iron, Trace metals | pH meter, Conductivity meter, UV-Spectrophotometer, Atomic Absorbtion Spectrophotometer, ICP-MS | |
322 | Uva Wellassa University | Mechanical Properties of Materials | Universal Testing Machine, Tensile Strength, Compressive strength | UTM is used to test the mechanical properties of materials such as tensile and compressive strength. It can accommodate many kinds of materials, ranging from hard samples, such as metals and concrete, to flexible samples, such as rubber and textiles. This diversity makes the UTM equally applicable to virtually any manufacturing industry. Other tests that can perform using the UTM includes seal strength test, bond strength test, gliding force test, coefficient of friction test, spring testing and food texture analysis. | Universal Testing Machine (UTM) | |
323 | Rajarata University of Sri Lanka | Gel Electrophoresis | techniques used to separate molecules of DNA, RNA, or protein on the basis of their size or electric charge. | DNA sequencing or mass spectrometry | it is used in DNA fingerprinting and the detection of genetic variants and proteins involved in health and disease as well as in the detection and purification of nucleic acids and proteins for research. | Gel Electrophoresis Unit- Cleaver Scientific (MSCHOICE10) |
324 | Uva Wellassa University | CNC Machine | Unmanned machining operations, Engineering Tool, Manufacturing Industry | NA | CNC machining is subtractive manufacturing technology, and it is a process used in the manufacturing sector that involves the use of computers to control machine tools like lathes, mills and grinders. This technique allows to machine components with high repeatability and precision, perform unmanned machining operations, improve production planning, and increase productivity. Here the parts are created by removing material from a solid block (called the blank or the workpiece) using a variety of cutting tools | CNC Machine |
325 | Uva Wellassa University | UV-Visible Spectroscopy | Optical Absorption of Transparent liquids, solids, thin-films and glass | light absorbed, transmitted, reflected by the sample, Concentration, Absorbing Wavelength | UV/VIS spectroscopy implies absorption/reflection measurements carried out in the ultraviolet and visible light spectrum. According to the Beer-Lambert law, which links the attenuation of light to the characteristics of the material through which the light passes, a sample’s absorbance is directly proportional to the concentration of the absorbing specimen. This technique is extensively used in research and analytical laboratories for the quantitative and qualitative analysis of all molecules and specific compounds that absorb ultraviolet and visible electromagnetic radiation. UV-Visible technique can be employed in impurity detection of compounds, concentration measurements, structure elucidation of organic compounds, studying chemical kinetics, and detection of functional groups etc. | UV-Visible Spectrometer |
326 | Rajarata University of Sri Lanka | Colony Counter | On an accurate count of bacterial colonies and cells | CFU/mL (colony-forming units per milliliter) for liquids and CFU/g (colony-forming units per gram) for solids. | Colony counters are used to estimate a liquid culture’s density of microorganisms by counting individual colonies on an agar plate, slide, mini gel, or Petri dish. | Rocker (Galaxy230), ColeParmer / UK (SC6 Plus) |
327 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Chromaticity | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Chromaticity | The monitoring parameter of this product is Chromaticity. It has automatic calibration, automatic temperature adjustment, and automatic probe cleaning capabilities. | LFS-2002(SD) Colority Water Quality Analyzer |
328 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Dissolved Oxygen | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Dissolved Oxygen | The monitoring parameter of this product is Dissolved Oxygen. It has the functions of automatic calibration, automatic temperature compensation, and automatic probe cleaning. | LFWCS-2008(DO) Dissolved Oxygen Water Quality Analyzer |
329 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Conductivity | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Conductivity | The monitoring parameter of this product is Conductivity. It has the functions of automatic calibration, automatic temperature compensation, and automatic probe cleaning. | LFWCS-2008(C) Conductivity Water Quality Analyzer |
330 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - pH | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | pH | The monitoring parameter of this product is pH. It has the functions of automatic calibration, automatic temperature compensation, and automatic probe cleaning. | LFWCS-2008(pH) pH Water Quality Analyzer |
331 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Turbidity | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Turbidity | The monitoring parameter of this product is Turbidity. It has the functions of automatic calibration, automatic temperature compensation, and automatic probe cleaning. | LFWCS-2008(TB) Turbidity Water Quality Analyzer |
332 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Methanal | Municipal Sewage, Pollution Source Discharge Water, Surface Water, Groundwater. | Formaldehyde | Formaldehyde is usually a colorless aqueous solution or gas with a pungent odor, easily soluble in water, and irritating to human eyes and nose. In the presence of excessive ammonium salt, the reaction of formaldehyde and acetylacetone would generate a yellow compound, which has the maximum absorption at the wavelength of 414nm. The absorbance(A) is measured and the absorbance is stable within 3h of color development. And the standard operating curve is searched based on value A, and the concentration of formaldehyde is then calculated. | LFS-2002(CHO) Methanal Water Quality Analyzer |
333 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water- Total Hardness | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Total Soluble (Ca, Mg) Hardness | This product is based on the principle of titration or spectrophotometry to determine the total soluble (calcium, magnesium) hardness in sample water. | LFS-2002 (HD) Total Hardness Water Analyzer |
334 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water- Iron | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Iron | The product adopts UV-Vis spectrophotometry, and through modular design, parameters can be switched according to needs. | LFS-2002 series heavy metal water quality analyzer |
335 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water- Manganese | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Manganese | The product adopts UV-Vis spectrophotometry, and through modular design, parameters can be switched according to needs. | LFS-2002 (Mn) Manganese water quality analyzer |
336 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Arsenic | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic Sewage. | Arsenic | The product adopts UV-Vis spectrophotometry, and through modular design, parameters can be switched according to needs. | LFS-2002 (As) - I- Arsenic water quality analyzer |
337 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water- Chromium | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic sewage. | Hexavalent Chromium | The product adopts UV-Vis spectrophotometry, and through modular design, parameters can be switched according to needs. | LFS-2002 (Cr) Hexavalent Chromium water quality analyzer |
338 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Nitrite Nitrogen | Surface Water, Groundwater, Seawater, Drinking Water Sources, Domestic sewage. | Nitrite Nitrogen | This product adopts N-(1-naphthalene) ethylenediamine dihydrochloride spectrophotometric method to detect nitrite nitrogen. A purple-red complex is formed in the environment of ℃, and the color of the solution is proportional to the content of nitrite nitrogen in the sample. The instrument determines the content of nitrite nitrogen in the water sample by photoelectric calorimetry. | LFS-2002 (NO₂) nitrite nitrogen water quality analyzer |
339 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Nitrate Nitrogen | Surface Water, Groundwater, Seawater, Drinking water sources, domestic sewage. | Nitrate Nitrogen | This product uses UV spectrophotometry to determine nitrate nitrogen and uses the absorption of nitrate ions at 220mm wavelength to determine nitrate. Through the difference in absorbance at 220nm and 275nm, the interference of dissolved organic matter was removed, and the concentration of nitrate nitrogen in the water sample was obtained. | LFS-2002 (NO₃) nitrate-nitrogen water quality analyzer |
340 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water- Total Phosphorus | Surface Water, Groundwater, Seawater, Drinking water sources, Domestic sewage. | Total Phosphorus | The product digests the sample with potassium persulfate and oxidizes all the phosphorus contained in it to orthophosphate. In an acidic medium, in the presence of antimony salt, orthophosphate reacts with ammonium molybdate to form a phosphomolybdic heteropolyacid, which is immediately reduced by ascorbic acid to form a blue compound. The total phosphorus content in the water samples was then measured by spectrophotometry. | LFS-2002 (TP) Total Phosphorus Water Quality Analyzer |
341 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water- Ammonia Nitrogen | Surface water, Groundwater, Seawater, Drinking water sources, Domestic sewage | Ammonia Nitrogen | This product uses salicylic acid spectrophotometry to determine ammonia nitrogen. In the presence of sodium nitroferricyanide, ammonium reacts with salicylate and hypochlorite ions to form blue compounds. Through photometric colorimetry, ammonia nitrogen is achieved. Full automation of the concentration detection process. The instrument can eliminate the interference of sample turbidity, chromaticity, substrate interference, and other factors in the results of ammonia nitrogen determination. The detection limit of ammonia nitrogen can reach 0.02mg/L, realizing high precision, low detection limit, high stability, and low maintenance of ammonia nitrogen. Fully automatic online monitoring. | LFS-2002 (NH) ammonia nitrogen water quality analyzer |
342 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Anionic Surfactant | Domestic Water, Drinking Water, Surface Water, Sewage and Wastewater | Anionic Surfactant | This product adopts methylene blue spectrophotometry. The anionic surfactant in the sample reacts with methylene blue to form blue salts. The intensity of the color is proportional to the concentration of the anionic surfactant, which can be calculated according to the color-developing photometric detection absorbance value. Concentration value of anionic surfactant. The instrument is based on the national standard or industry standard and has the characteristics of simple operation, a high degree of automation, easy maintenance, and low cost of consumables. | LFS-2002 (LAS) Anionic Surfactant Water Quality Analyzer |
343 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Cyanide | Municipal Sewage, Pollution Source Discharge Water, Surface Water, Groundwater. | CN- | This product adopts isonicotinic acid-barbituric acid spectrophotometry, according to the fact that cyanide and chloramine-T can generate cyanogen chloride under the action of active chlorine, and then react with an isonicotinic acid-barbituric acid reagent to generate violet blue The degree of the colour change of the solution is proportional to the concentration of cyanide in the water, and the concentration of cyanide can be obtained according to the color photometric detection of the color. | LFS-2002 (CN) Cyanide Water Quality Analyzer |
344 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Heavy Metals | Surface Water, Groundwater, Seawater, Drinking Water, Industrial Wastewater, Domestic Sewage. | Pb, Cd, Zn, Cu | The product is based on the electrochemical detection technology of anodic stripping voltammetry, which eliminates the influence of heavy metal inter-compounds on the detection during the electrodeposition process, and the detection period is less than or equal to 15min. Monitoring parameters include zinc, cadmium, lead and copper | LFEC-2006 Heavy Metal Water Quality Analyzer |
345 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Chemical Oxygen Demand | Surface Water, Groundwater, Seawater, and Drinking Water | COD | The product adopts the detection principle of the potassium permanganate oxidative titration method. The pretreated water sample is oxidized and digested by potassium permanganate under constant temperature conditions, and then reduced by adding excess sodium oxalate solution and titrated with potassium permanganate solution. For reducing agents, the titration endpoint is judged by absorbance or redox potential, and the volume of potassium permanganate volume calculates the permanganate index value dropped back. The instrument has two detection methods of acidity and alkalinity. When the chloride ion concentration in the solution is high, the alkaline potassium permanganate oxidative titration method can be used to eliminate the interference of chloride ions in the solution. | LFS-2002 (CODMn) Permanganate Index Water Quality Analyzer |
346 | China-Sri Lanka Joint Research and Demonstration Centre for Water Technology | Water - Volatile Phenol | Municipal sewage, Pollution source Discharge water, Surface water, Groundwater. | C6H6O | The product adopts the detection principle of 4-amino-antipyrine spectrophotometry, and the combination of online distillation and constant gas flow is preferred, which greatly shortens the distillation and separation time of volatile phenol. Amino-antipyrine reacts to generate orange-red indoxyl-antipyrine dye, and the automatic monitoring of volatile phenol concentration is completed by colorimetric photometric detection. | LFS-2002 (Phe) Volatile Phenol Water Quality Analyzer |
347 | Uva Wellassa University | Chemical Properties | Functional Groups, Chemical Bonds, IR absorption | FTIR offers quantitative and qualitative analysis for organic and some inorganic samples, thus reveal the composition of solids, liquids, and gases. It can identify chemical bonds in a molecule by producing an infrared absorption spectrum. FTIR is an effective analytical instrument for detecting functional groups and characterizing covalent bonding information. FTIR is a common technique in analyzing samples in the fields of environmental monitoring, forensics, pharmaceuticals, quality control, etc. The FTIR spectroscopy is used to identify compounds such as compounded plastics, blends, fillers, paints, rubbers, coatings, resins, and adhesives. | FTIR Spectrometer | |
348 | Uva Wellassa University | Crystallographic Analysis | Crystal Structure, Material's Crystalline phases, Chemical Composition | Crystal Structures, Lattice Parameters, Strain, Grain size, Phase Composition, Crystal defects | X-ray diffraction (XRD) is a powerful non-destructive technique for characterizing crystalline materials. X-ray diffraction peaks are produced by constructive interference of a monochromatic beam of X-rays scattered at specific angles from each set of lattice planes in a sample. This technique is commonly used in many fields, including the Pharmaceutical industry, forensic science, geological science, ceramic and glass industry, etc. For example, in the ceramic industry, XRD is used to determine elemental composition analysis, the arrangements of those elements, defects, and quantity of elements and compounds. | X-Ray Diffractometer (XRD) |
349 | Rajarata University of Sri Lanka | Micro Manipulator | Trinocular Inverted Microscope | Genetic transformation and Microbial inoculation in live cells , In-Vitro fertilization | Observation method - Brightfield, Apodized Phase Contrast*1, Phase Contrast, Nikon Advanced Modulation Contrast*2, DIC, Emboss Contrast*3, Epi-Fluorescence, Spindle Observation | Gene gun, Electrophoras |
350 | Coconut Research Institute of Sri Lanka | Pathogen Detection | Phytoplasma, Bacteria and Fungi | Determination of Cycle Threshold (CT) value of samples | Real Time PCR System provide more reliable results of pathogen detection. It is a modern and versatile technique providing different ways of analysis including Standard curve, Relative standard curve, Comparative CT, Genotyping and Presence/absence. System has run time of less than 2 hours and five-color detection enable user to use a broad range of fluorophores including FAM™/SYBR® . Green I, VIC®/JOE, NED™/ TAMRA™/ Cy3™, ROX™/Texas Red®, and Cy5™ dyes for greater assay versatility. Supports 96-well format plates and 0.2 mL tubes | Applied Biosystems 7500 Real-Time PCR System |
351 | Coconut Research Institute of Sri Lanka | Food Quality | Solid and Liquid Food Samples with fat | Free Fatty Acids in 1 minutes, Peroxide Value in 4 minutes, Iodine Value in Palm Oil in 2 minutes, | The speed and ease of use of CDR FoodLab® is analytical methods become competitive advantages for food industries producing oils or fats, or that employ them as ingredients.CDR FoodLab® can determine:Free Fatty Acids in 1 minutePeroxide Value in 4 minutesp-Anisidine Value in 2 minutesSoaps in 2 minutesIodine Value in Palm Oil in 2 minutesPolyphenols on Olive Oil in 5 minutesCDR FoodLab® is the chemical analysis system designed and developed to provide accurate results at every step of the production process: the system is so easy to use that it can be utilized not only in a laboratory, but real time at the production plant for process control or quality control, even by staff with no previous specific lab tech experience. | Food Lab |
352 | Rajarata University of Sri Lanka | Drying & dehydration | Food , Fodder, liquids and extracts (plant & non-plant) | Dry matters | Freeze Drying is a process of removing moisture/water or other solvents in a sample, under the frozen and vacuum conditions. | Freeze dryer |
353 | Rajarata University of Sri Lanka | Digital Droplet PCR | QIAcuity® Digital PCR System | Absolute quantification, Mutation detection, Genome editing, Copy number variation, Gene expression | The QIAcuity Digital PCR System makes absolute quantification accessible and affordable for all laboratories. The walk-away automation integrates and streamlines the entire digital PCR workflow of partitioning, thermocycling and imaging into a single instrument with minimal hands-on time. It is also easy to adapt your current qPCR assays to the QIAcuity Digital PCR System. No change in plate handling is required when coming from qPCR, assuring fast assay setup and quick results in under 2 hours. | |
354 | Rajarata University of Sri Lanka | Gas Analysers | Infrared Gas Analysis Systems | CO2, H20, Photosynthesis, Respiration, Transpiration, Stomatal Conductance, Leaf Temperature, Soil Respiration, Insect Respiration | These equipment are used for leaf gas exchange & chlorophyll fluorescence measurement. | LiCOR BioScience Portable Photosynthesis Systems, CID BioScience Handheld Photosynthesis Systems, PP Systems CI-340 Handheld Photosynthesis System |
355 | Rajarata University of Sri Lanka | Real Time PCR Machine | Rotor Gene Q 5 plex | Up to 6 separate channels (365–680 nm excitation, 460–750 nm detection), Fixed optical path, separate high-power excitation LEDs and emission filters per channel, Highly sensitive photomultiplier (PMT) detector with gain setting (sensitivity control), Dynamic range: 10 orders of magnitude (assay dependent), PCR Tubes 0.2 ml: 0.2 ml x 36 wells, 15–50 µl recommended reaction volume, individual tubes with caps | Quantitative, real-time PCR is a precision science that places high demands on the instrument, chemistry, and software. Highthermal and optical uniformity, short equilibration times, and fast ramping rates are critical for precise and rapid quantitativeanalysis. Sensitivity, speed, and specificity are also highly dependent on the performance of the DNA polymerase andreaction components. | |
356 | Coconut Research Institute of Sri Lanka | Fat Content | Coconut related products, other Food & Feed ,Pharmaceuticals, Sewage water, Mineral oils, Lubricants and Soils. | Determine crude fat or other components soluble in organic solvents | fat extraction system is specially optimized to determine crude fat or other components soluble in organic solvents according to the universally known Solvent extraction method, including both Randall and Twisselmann methods. | Fat Extractor |
357 | Rajarata University of Sri Lanka | In-vitro characterisation of pharmaceuticals and toxins | drig discovery, pharmacology, physiology, toxinology | contractile force of skeletal muscles, contractile force of smooth muscles in blood vessles and organs | ||
358 | Coconut Research Institute of Sri Lanka | Dietary fiber | Coconut related food products and other Food and Beverage with Fibre | Determination of dietary fiber in Coconut products, other food and agricultural products | The analytical procedure for the determination of dietary fiber involves a series of digestions of the sample by thermostable enzymes using the enzymatic digester GDE, which operates in accordance with the official AOAC method for the determination of total dietary fiber. | Enzymatic Digestion Unit and Filtration Unit |
359 | Rajarata University of Sri Lanka | Fluorescent Microscope | Microscopy, Conventional, Light | Fluorescent label proteins, Color Separation Filters | The motorized operations of the BX-RFAA motorized reflected fluorescence illuminator used with thissystem can be controlled from the BX-UCB control box and U-HSTR2 hand switch (the illuminator canalso be interlocked with other motorized equipment using the BX2 software for PC).Motorized operations: · Turret switching of mirror units· Insertion/removal of the shutter· Activation of motorized revolving nosepiece connector | Confocal microscopy |
360 | Rajarata University of Sri Lanka | Surface Analysis | Any solid object | Partial Size, Elemental Composition | Use for the examination and analysis of micro- and nanoparticle imaging characterization of solid objects. Typically can magnify images around 300,000 times (up to 10 nm). | Scanning electron microscope (SEM) |
361 | Coconut Research Institute of Sri Lanka | Protein content | Coconut related food products , other Food and Beverage with Protein, Soils, fertilizers and Waste waters | Estimate the protein content in sample | internationally recognized method for estimating the protein content in foods, soils, waste waters, fertilizers and other materials. | Kjeldhal Distillation Unit |
362 | Rajarata University of Sri Lanka | Liquid Nitrogen | Liquid Nitrogen | About 20 L of liquid nitrogen can be produced at a time | Liquid Nitrogen Plant | |
363 | Coconut Research Institute of Sri Lanka | Fiber Content | Coconut related food products and other Food and Beverage with Fibre | Determination of crude fiber in feed, food and other agricultural products | Fiber Analyzers suitable for raw fiber extraction, conventionally known as an indigestible residue. | Fiber Analyzer |
364 | Rajarata University of Sri Lanka | Gases, volatiles and organic molecules | Food, feed, pollutants, aromatic compounds | composition and concentration of gases/volatiles | Separation and detection of gaseous chemical compounds qualitatively and quantitatively | Gas Chromatography |
365 | Rajarata University of Sri Lanka | Product Texture | Food, Cosmetics, Pharmaceuticals, Materials and Packaging | Hardness, adhesiveness, springiness, gumminess, cohesiveness, chewiness, Penetration depth | Texture Analyzer | |
366 | Rajarata University of Sri Lanka | Trace & Heavy metal | Water, Soil, Sludge, Plant, Milk, Fertilizer | Concentration of Trace & Heavy metals | A trace-level, elemental analysis technique that uses the emission spectra of a sample to identify, and quantify the elements present. Simultaneous, sequential analysis of multiple elements and high number of measurable elements is possible. | Inductively couple Plasma Optical emission spectrometer |
367 | Coconut Research Institute of Sri Lanka | Elements in solution | Food and beverage, Water, Pharmaceuticals | Concentration of Individual elements in ppm and ppb level | Atomic absorption spectrometry (AAS) is used primarily to determine the concentrations of individual elements in solution. As such, AAS is used in food and beverage, water, clinical research, and pharmaceutical analysis. It is also used in mining operations to determine, metal concentration. | ICP-OES |